4-1
SECTION IV
TROUBLESHOOTING
4-1
LEAKAGE
Analysis of general operational experience with diffusion pumps indicates that certain locations are
more prone to the incidence of leaks. The following locations should be checked first if leakage is the
suspected cause of poor system performance.
a.
Inlet and foreline connections.
b.
Drain and fill plugs.
c.
Other compression fittings, such as high-vacuum gauges in the system.
d.
Threaded connections, such as a foreline gauge.
4-2
OUTGASSING
High-vacuum systems, even without external leakage, can have high gas loads due to outgassing
from internal surfaces or processes. The pressure in the system is a result of gas load divided by
pumping speed (p = Q/S). If the gas load (Q) exceeds the maximum throughput capability of the diffu-
sion pump, the diffusion pump will not function and the pumping action will essentially be due to the
mechanical backing pump.
To estimate the gas load, isolate the system from all pumps after evacuation and measure the rate of
pressure increase. The gas load can be estimated as follows:
V x
∆
P
Q = ______
∆
t
where V is the isolated volume,
∆
P is the pressure rise, and
∆
t time period of measurement.
4-3
POOR PUMP OR SYSTEM PERFORMANCE
Before proceeding with a program of step-by-step troubleshooting, check the performance and accu-
racy of the vacuum gauges used on the system. Table 4-1 shows common faults, and lists the proba-
ble cause and corrective actions to correct for poor performance.
Table 4-1 Troubleshooting
Fault
Probable Cause
Corrective Action
Leaks in system, virtual or real
Locate and repair.
High process gas load
Measure gas load, eliminate
cause.
System dirty
Clean system to reduce
outgassing.
Summary of Contents for HS-20
Page 18: ...Installation 1 3 Figure 1 2 Outline Drawing HS 20 Diffusion Pump with ASA Flanges ...
Page 24: ...Installation 1 9 Figure 1 4 200 240 400 430 440 480 V Wiring Diagram HS 20 Diffusion Pump ...
Page 25: ...Installation 1 10 Figure 1 5 380 415 V Wiring Diagram HS 20 Diffusion Pump ...
Page 35: ...Maintenance 3 6 Figure 3 2 20 inch Jet Assembly ...
Page 41: ...Maintenance 3 12 ...