VARI
❋
LITE - VLX3 W
ASH
L
UMINAIRE
U
SER
’
S
M
ANUAL
10
17 December 2012
02.9703.0001 A
Power and Data Cabling Requirements
AC Power
WARNING:
DO NOT connect to three-phase Delta service in countries with 240 volt power.
WARNING:
DO NOT connect or disconnect energized power cable at fixture (under load). Turn off
circuit breaker (or completely de-energize circuit) before connecting or disconnecting power cable at
fixture. Power is only removed from the fixture by disconnecting power cable from source or turning
off source circuit breaker.
WARNING:
It is not recommended to power any VARI
❋
LITE luminaire from a dimmer - even in
'NONDIM' mode. Dimmer and non-dim modules are not suitable sources of power because their
output modifies the AC wave form. This may work for a short time, but will eventually result in power
problems, luminaire mis-operation and/or failure and may void the luminaire’s warranty.
The luminaire requires standard AC power distribution from 100-240 VAC, 50/60 Hz in order to
power all internal electronics and motors. It is equipped with a 3-pole Neutrik PowerCon locking
connector (with contacts for line, neutral, and premating safety grounds) for the purpose of AC input.
*International (Harmonized) Standard
Wire*
Connection
Green/Yellow
AC Ground
Blue
AC Neutral
Brown
AC Line
Summary of Contents for VLX3
Page 1: ......
Page 13: ...FOREWORD 02 9703 0001 A 17 December 2012 xi...
Page 14: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL xii 17 December 2012 02 9703 0001 A...
Page 36: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL 20 17 December 2012 02 9703 0001 A Notes...
Page 84: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL 68 17 December 2012 02 9703 0001 A Notes...
Page 97: ......