C
HAPTER
3. M
AINTENANCE
P
ROCEDURES
3-33
02.9631.0010
CONFIDENTIAL
15 Jan 98
3.2.2
Luminaire Fault Isolation Procedures
3.2.2.1
Luminaire Powers Up, But Will Not Calibrate
Assuming the following:
•
Console is powered up and working properly.
•
Repeater unit is properly connected and working.
•
Lamp cable is good.
Step 1.
At VL2B/VL2C lamp input connector, check connection to
lamp run cable. Ensure good connection.
Step 2.
Hard reset luminaire by removing and then resupplying power
to repeater unit.
Step 3.
Check form and function setting.
a. Access motherboard. Refer to Motherboard Removal and
Replacement paragraph.
b. At the form and function switch, the bit number represented
by the switch should be read off the PCB and not the switch
itself. The switch depressed on the "open" side represents a
binary 1. The form and function switch settings is as
follows:
7
6
5
4
3
2
1
0
OPEN
PUSH TO SET OPEN (1)
Unit
Binary
Decimal
VL2B
00001010
10
VL2C
00001011
11
Step 4.
Ensure proper CIB, LVS, and LCB connections.
a. At motherboard, ensure all cables are properly and securely
connected. Ensure memory card pins are seated properly in
LCB.
b. At motherboard, ensure circuit cards are seated properly.
Step 5.
If symptom persists, replace CIB, LCB, and/or LVS. Refer to
Low Voltage Supply, Lamp Control Board, and Control
Interface PCB Removal and Replacement paragraphs.