Summary of Contents for VL2202

Page 1: ...VL2200 Series Spot Luminaires U s e r s M a n u a l 02 9673 0001...

Page 2: ...081 BE FR GB 0192882 BE FR GB 0140994 BE FR GB 0060068 BE FR GB France Design Reg No 335132 335147 Spain Patents No 2090191 2084289 2082384 2058071 2020960 0548328 Spain Utility Model No 2031748 Spain...

Page 3: ...failure and the name of the registered user or organization If available you should have your sales invoice to establish the date of sale as the beginning of the warranty period The form at the end of...

Page 4: ...nterference to radio communica tions Operation of this equipment in a residential area is likely to cause harmful inter ference in which case the user will be required to correct the interference at h...

Page 5: ...only with certain Philips and Osram HID lamps Note lamp type MSR400 MSR575HR etc before replacing lamps Installing another type of lamp may be hazardous 2 Luminaires may be mounted on any type of sur...

Page 6: ...tion which can cause serious skin burn and eye inflammation Additionally arc lamps operate under high pressure at very high temperatures Should the lamp break there can exist a danger of personal inju...

Page 7: ...MSR575HR etc bevor Sie die jeweiligen Lampen ersetzen Die Installation eines anderen Lampentyps kann gef hrlich sein 2 Scheinwerfer k nnen auf jeder beliebigen Oberfl che montiert werden solange Sie d...

Page 8: ...genlampen erfolgt unter Hochdruck und bei hohen Temperaturen Sollte die Lampe zerbrechen besteht die Gefahr von K rperverletzung bzw von Feuer das von Lampenteilen ausgel st werden kann 4 Tragen Sie b...

Page 9: ...s lampes Philips et Osram HID V rifier le type de lampe MSR400 MSR575HR etc avant de remplacer les lampes L installation d un autre type de lampe peut poser un danger 2 Les luminaires peuvent tre fix...

Page 10: ...e graves br lures sur la peau et une inflammation des yeux De plus les lampes arc fonctionnent sous haute tension de tr s hautes temp ratures Si la lampe se casse les particules de la lampe cass e peu...

Page 11: ...l mparas HID Philips y Osram Tome nota del tipo de l mpara MSR400 MSR575HR etc antes de reemplazarla Instalaci n de otro tipo de l mpara puede ser peligroso 2 Las luminarias se pueden instalar en cua...

Page 12: ...s a la piel e inflamaci n a los ojos Adem s las l mparas de arco operan a alta presi n y muy alta temperatura Si la l mpara se rompe puede existir el peligro de lesiones al personal o un incendio ocas...

Page 13: ..._KH P H P Q X Q X _KH P s H P T Q X _KQo 4 UV 2 q P x T 4 Ef 1 VARI LITE zU Philips Osram HID fJ 3 fJ d fJ MSR400 MSR575HR z fJ zU Q X 0 2 2 J Y f Q X EXo d EXo 4 VARI LITE zU H 6 T Ef 1 VARI LITE zU...

Page 14: ...2 9673 0001 A T 2 UV Ef 1 VARI LITE zU UV HID 2 J fJ fJ _f o zU P _f o Y 2 T q P Ef zU P zU fPo f U zU P fJ fJ d zU fJ 2 fJ c 64 fJ o v o A 6 o q P 4 H cP fJ U fJ H o fJ zU I fJ fJ T RF 1 Class A 8c u...

Page 15: ...ion Power and Data Cabling Requirements Power 11 Current vs Voltage 12 Data Cables 13 Recommended Cable Types Manufacturers 14 Male Termination Connector 15 Female Termination Connector 15 Loopback Co...

Page 16: ...Wheel 34 Beam Control 35 Beam Iris 35 Edge 35 Strobe 35 Zoom 35 Luminaire Timing Luminaire Timing Channel Information 36 Control Channel Functions 42 Updating Software Reprogramming Luminaires 43 Inst...

Page 17: ...ptions 75 Appendix A Troubleshooting and Maintenance Troubleshooting Protecting Your Warranty 87 Troubleshooting Guide 88 Routine Maintenance Lamp Replacement 93 Color Filter Replacement 95 Fixed Gobo...

Page 18: ...VARI LITE VL2200 SERIES SPOT LUMINAIRE USER S MANUAL xviii 22 May 01 02 9673 0001 A This page intentionally blank...

Page 19: ...is available for extended maintenance of VL2200 Series Spot Luminaires This manual is available in both printed and electronic PDF formats VL2200 Series Spot Luminaire Service Manual 02 9673 0010 Trou...

Page 20: ...xt Conventions The following styles and meanings are used throughout this manual Button Front panel button Example Press Menu Up Down arrows Press either Up or Down arrow button at Menu Display MENU M...

Page 21: ...02 9673 0001 A 22 May 01 3 Description Description Description Description Features Components CHAPTER 1 CHAPTER 1...

Page 22: ...VARI LITE VL2200 SERIES SPOT LUMINAIRE USER S MANUAL 4 22 May 01 02 9673 0001 A This page intentionally blank...

Page 23: ...hanges and smooth timed beam angle changes Rotatable gobo wheel which contains five individually rotatable indexable gobos Two 12 position wheels each providing 11 easily loaded positions and 1 open f...

Page 24: ...trols Head Assembly Upper Enclosure Truss Hook Assembly AC Input Cable Yoke Bracket Assembly Assembly Removable Lamp Assembly to access lamp for replacement Beam Adjustment Controls Vertical Horizonta...

Page 25: ...splay orientation and operation LED Indicators The LED indicators report the status of power and data to the luminaire Changes a value or Displays the menu or if at first level the current address Sel...

Page 26: ...VARI LITE VL2200 SERIES SPOT LUMINAIRE USER S MANUAL 8 22 May 01 02 9673 0001 A This page intentionally blank...

Page 27: ...02 9673 0001 A 22 May 01 9 Installation Installation Installation Installation Power and Data Cabling Requirements Installation Procedures Powering Up Addressing CHAPTER 2 CHAPTER 2...

Page 28: ...VARI LITE VL2200 SERIES SPOT LUMINAIRE USER S MANUAL 10 22 May 01 02 9673 0001 A This page intentionally blank...

Page 29: ...AC input cable may require a different connector If required install a new connector meeting your requirements using the following wire color code reference International Harmonized Standard WARNING...

Page 30: ...nd all motors sequencing Table 2 1 VL2201 Current vs Voltage Voltage 60Hz Current 90 0 8 2 100 0 7 1 110 0 6 3 120 0 5 8 130 0 5 3 140 0 4 8 180 0 3 8 190 0 3 5 200 0 3 3 210 0 3 2 220 0 3 1 230 0 2 9...

Page 31: ...w capacitance Two twisted pairs Foil and braid shielded 24 AWG min gauge for runs up to 1000 feet 300m 22 AWG min gauge for runs up to 1640 feet 500m Note Microphone type cables and other general purp...

Page 32: ...gh Temp Plenum cable 200 8102 2 100 PVC 24 UL2919 80 8132 2 120 PVC 28 UL2919 80 8162 2 100 PVC 24 UL2493 60 82729 2 100 PTFE 24 High Temp Plenum cable 200 88102 2 100 PTFE 24 High Temp Plenum cable 2...

Page 33: ...r luminaire To construct your own connector you will need the following components 5 pin female XLR connector Two 1 4W 5 120 ohm resistors Note A female termination connector is available as an access...

Page 34: ...Ensure power is removed from luminaire 2 Remove lamp from shipping box 3 At backcap using slotted screwdriver or fingers turn captive knob until loose 4 Slide backcap away from head assembly it will r...

Page 35: ...truss hook bracket are required When attaching more than one point on a single bracket the attach points must be spaced as far apart as possible using the supplied mounting holes A safety cable is rec...

Page 36: ...to lock in place Ensure brackets are locked securely Always face brackets in same direction as shown WARNING Ensure that the bracket locking mechanism is fully seated after the bracket is installed on...

Page 37: ...lows a Connect one end of cable to luminaire handle b Loop at least once around truss pipe and attach other end of cable to other handle 4 Connect power and data cables according to procedure given in...

Page 38: ...th Consult your console documentation for more information To connect power and data 1 Connect data cable from console to first luminaire in chain at DATA IN connector 2 If required connect additional...

Page 39: ...a is present All internal mechanisms also move to their home or DMX defined positions Subsequently depending on the luminaire s setting for Lamp Power Up State refer to Menu System Functions on page 6...

Page 40: ...stalled it will be necessary to align the lamp to optimize the beam for either the peaked or flat field depending on the luminaire model Knobs located at the luminaire s backcap will allow adjustment...

Page 41: ...n button until DMX appears Press Enter 3 Press Up or Down to until desired mode is reached 8 16 E 8 or E 16 Press Enter to set mode See DMX Modes on page 29 for more information Note Which mode is use...

Page 42: ...a DMX or Virtuoso starting address 1 Press Menu 2 Press Up Down arrows until ADDR Address appears Press Enter 3 Press Up Down arrows to access DMX DMX console control or VIRT Virtuoso console control...

Page 43: ...02 9673 0001 A 22 May 01 25 Operation Operation Operation Operation Color Gobo Control DMX Modes DMX Mapping Luminaire Timing Updating Software CHAPTER 3 CHAPTER 3...

Page 44: ...VARI LITE VL2200 SERIES SPOT LUMINAIRE USER S MANUAL 26 22 May 01 02 9673 0001 A This page intentionally blank...

Page 45: ...are installed on the Rotating Gobo Wheel nearest to front lens This wheel has six positions one being open Color and gobo wheels offer partial frame control and various spin rates in either direction...

Page 46: ...673 0001 A Standard Rotating Gobos Pebbles Dust Medium Night Sky Leaves Vertical Wave Block Tribal Liquid Alpha Breakup Circles Bars Breakup Breakup Breakup Rays 2 3 4 5 6 7 8 9 10 11 12 1 5 Facet Pri...

Page 47: ...tensity 1 Pan 2 Pan 2 3 Tilt 3 Tilt 4 5 Fixed Gobo 4 Fixed Gobo 6 Color 5 Color 7 Iris 6 Iris 8 Edge 7 Edge 9 Strobe 8 Strobe 10 Zoom 9 Zoom 11 Rot Wheel 10 Rot Wheel 12 Gobo Index 11 Gobo Index 13 Co...

Page 48: ...DMX 0 255 Wheel Position Value DMX 0 255 Wheel Position 0 0 Open Frame 1 29 1 30 2 12 31 1 3 32 4 13 33 2 5 34 6 35 Full Frame 3 7 14 36 3 8 37 9 Half Frame 15 38 4 10 39 11 40 12 16 41 5 13 42 14 17...

Page 49: ...03 70 104 28 71 Full Frame 5 41 105 72 106 73 42 107 Full Frame 7 29 74 108 75 109 30 76 43 110 77 111 78 44 112 31 79 113 80 Half Frame 114 81 45 115 32 82 116 Half Frame 83 46 117 33 84 118 85 119 8...

Page 50: ...167 53 135 66 168 136 169 137 170 Half Frame 54 138 67 171 139 172 55 140 68 173 141 174 142 175 56 143 Full Frame 9 69 176 144 177 57 145 178 146 70 179 Full Frame 11 147 180 58 148 71 181 149 182 59...

Page 51: ...p 202 92 235 Stop 203 236 Stop 80 204 93 237 Spin S CW 205 238 206 Half Frame 239 81 207 94 240 208 241 82 209 95 242 210 243 211 244 83 212 96 245 213 246 Spin M CW 84 214 97 247 215 248 216 Spin F C...

Page 52: ...e DMX 0 255 Wheel Position 0 84 0 215 Index Position 85 216 Fast Spin CW 86 90 217 232 Variable Rates 91 233 Slow Spin CW 92 234 237 Stop 93 238 Slow Spin CCW 94 99 239 254 Variable Rates 100 255 Fast...

Page 53: ...tion 0 0 Closed 100 255 Open Table 3 5 DMX Map for Edge Value DMX Value Action 0 0 Blooms In 100 255 Blooms Out Table 3 6 DMX Map for Strobe Value DMX Value Action 0 0 2 Open 1 3 5 Closed 2 6 7 Slow R...

Page 54: ...tc 2 Decide which fixtures and which parameter groups will use timing chan nels Timing channels work only if all channels affected by the timing channel are in the same part of the cue 3 Assign a valu...

Page 55: ...9673 0001 A 22 May 01 37 Table 3 8 Channel Function Timing Channel Relationship Channel Function Timing Channel Focus Time Color Time Beam Time Pan Hi Byte Lo Byte Tilt Hi Byte Lo Byte Color Gobo Rot...

Page 56: ...1 2 42 8 4 7 1 4 17 43 8 6 3 8 1 6 44 8 8 9 1 8 45 9 4 10 2 18 46 9 2 11 2 2 47 9 4 12 2 4 19 48 9 6 5 13 2 6 49 9 8 14 2 8 50 10 6 15 3 20 51 10 2 16 3 2 52 10 4 17 3 4 53 10 6 7 18 3 6 21 54 11 19...

Page 57: ...23 109 33 29 74 19 43 110 33 75 20 111 34 30 76 20 44 112 34 77 20 113 34 78 21 114 35 31 79 21 45 115 35 80 21 116 36 81 22 46 117 36 32 82 22 118 36 83 23 119 37 33 84 23 47 120 37 85 23 121 38 86...

Page 58: ...85 217 170 182 65 218 180 183 70 86 219 180 72 184 70 220 180 185 75 221 190 73 186 75 87 222 190 187 75 223 200 188 80 88 224 200 74 189 80 225 200 190 85 226 210 75 191 85 89 227 210 192 85 228 210...

Page 59: ...A 22 May 01 41 241 270 248 290 95 242 270 249 300 243 270 98 250 300 244 280 251 310 96 245 280 99 252 310 246 290 253 310 97 247 290 254 310 100 255 Follows Cue Data Table 3 9 Timing Channels Map Con...

Page 60: ...alue for desired action for example 84 for reset Hold value for 3 seconds Note A numerical keypad is required for sending values An encoder or fader does not allow for a snap value change which is req...

Page 61: ...ard Note Up to 32 luminaires can be programmed at the same time if they are data linked together Refer to Connecting Data and Power on page 20 Programming more than 32 luminaires will require programm...

Page 62: ...L2000Download exe program from Vari Lite VL2000 support webpage 1 From PC that will be used to operate software connect to Vari Lite VL2000 support webpage at www vari lite com connect to the Vari Lit...

Page 63: ...ton is the equivalent of executing all of the specific software version buttons described above They will be executed one at a time in the order they appear in the window This button can be used when...

Page 64: ...any data connected the normal standby cycle of the Rx LED is 2 sec on 2 sec off 5 Once download is complete luminaire will automatically recalibrate Once recalibration is complete luminaire is ready...

Page 65: ...connector is required at the final luminaire in the link and a female termination connector is required at the master luminaire Refer to page 15 for more information regarding the construction of thes...

Page 66: ...ALL cabling is the 5 conductor type Note Without any data connected the normal standby cycle of the Rx LED is 2 sec on 2 sec off Note The number of blocks displayed will be less in a luminaire to lumi...

Page 67: ...02 9673 0001 A 22 May 01 51 Menu System Menu System Menu System Menu System Operation Mapping Cues and Sequences Self Tests CHAPTER 4 CHAPTER 4...

Page 68: ...VARI LITE VL2200 SERIES SPOT LUMINAIRE USER S MANUAL 52 22 May 01 02 9673 0001 A This page intentionally blank...

Page 69: ...ontrolled by four buttons These buttons function as follows Menu button Displays the menu or if at first level the current address Enter button Selects the current menu option or stores current data v...

Page 70: ...ion To assist in reading the Menu System if the luminaire is installed in a hanging position the display read out orientation can be changed so that it still reads from left to right Keep in mind that...

Page 71: ...Press Enter 3 Press Up Down arrows to access DisP Display Press Enter 4 Press Up Down arrows to select either 30s 30 sec 5M 5 minutes 10M 10 minutes or ON on indefinitely Press Enter to set Decimal P...

Page 72: ...Pressing Enter and Up at the same time Lamp On Pressing Enter and Down at the same time Lamp Off Pressing Menu and Up at the same time Recalibrate Pressing Menu at Power up interrupts calibration See...

Page 73: ...no errors Table 1 Error Messages Display Message OK No Errors Found B1M1 Whl2 NoSn Aux Board 1 Motor 1 Wheel 2 Sensor Not Found B1M1 Whl2 SAct Aux Board 1 Motor 1 Wheel 2 Sensor Always Active B1M2 Dim...

Page 74: ...Always Active SRCH FOR BRD1 Attempting to communicate with Board 1 SRCH FOR BRD2 Attempting to communicate with Board 2 TILT ENCR FAIL Tilt Encoder Failure TILT NO SENS Tilt Sensor Not Found TILT SEN...

Page 75: ...nu stop MODE DATA cXXX data value value Sens Pan Tilt Whl1 Whl2 Dimm Gobo IndX Fixt STAT Cal Modl LId pg 1 model OK scrolls errors or displays OK Ver FHrs Dnld pg 2 pg 1 pg 2 OK DSEQ OK STST STST STST...

Page 76: ...umulative of Operation Hours Not editable Strk of Lamp Strikes XXXX of Strikes not editable RHrs Reset Lamp Hour and Lamp Strike Counters OK P T Pan and Tilt Options Move Position Recovery Enab Enable...

Page 77: ...ct XXX Data Indx Rotating Gobo Index XXX Data Edge Edge XXX Data Zoom Zoom XXX Data Time Timing Data ITim Dimmer Intensity Time XXX X Data FTim Focus Time XXX X Data CTim Color Time XXX X Data BTim Be...

Page 78: ...e Dim1 Min Max Dimmer Test Dim2 Min Max Dimmer Test Dim3 Dimmer Test Str Strobe Test Cwhl Color Wheel Cwl1 Color Wheel Test Cwl2 Color Wheel Test Cwl3 Color Wheel Test FGob Fixed Gobo Wheel FG 1 Fixed...

Page 79: ...STST Sensor Test in Progress PASS FAIL Whl2 Wheel 2 EOT Sensor STST Sensor Test in Progress PASS FAIL Dimm Dimmer Strobe EOT Sensor STST Sensor Test in Progress PASS FAIL Gobo Gobo Select EOT Sensor...

Page 80: ...r initiates automatic playback of a cue sequence at power up CUE BTim Beam Time Accepts timing value for beam time C ON On after Calibra tion Configures arc luminaire so that lamp will strike after ca...

Page 81: ...feature FTim Focus Time Accepts timing value for focus time Gobo Gobo Select Specifies rotating gobo select for manual control Man or gobo select EOT sensor for testing Test Indx Gobo Index Specifies...

Page 82: ...wise DisP turns on a function or turns on a menu item P UP Lamp Power Up Accesses options for lamp power up on off or after calibration P T Pan Tilt Accesses pan and tilt options for DMX function syst...

Page 83: ...ystem Tests Accesses diagnostic tests for internal mechanisms Tilt Tilt Specifies tilt function for manual control Man or tilt encoder for testing Test Time Timing Data Allows manual setting of timing...

Page 84: ...stored in a master luminaire Playing a cue sequence for all luminaires in the data link is triggered by a master luminaire using the PSEQ Play Sequence command The cue follow time FLTM is taken from t...

Page 85: ...be the basis of the cue to be stored To clear all input data and timing values from previous tests or cues cycle power to the luminaire with DMX data cables disconnected This will reset parameter s da...

Page 86: ...isplayed is the cue number to be stored 4 Press Enter to store cue Number will increase by one for next cue to be stored 5 Repeat for remaining cues To delete a cue 1 Press Menu 2 Press Up Down arrows...

Page 87: ...pears Press Enter 3 Press Up Down arrows until PSEQ appears Press Enter and the sequence will play The active cue will be shown in the display Enter to start Menu to stop To change the follow time in...

Page 88: ...until SEQ appears Press Enter 4 Press Up Down arrows to toggle between ISEQ and MSEQ Press Enter to select mode To make a sequence AutoPlay at power up 1 Press Menu 2 Press Up Down arrows until Cue ap...

Page 89: ...luminaire can be placed in any position for testing without movement occurring In order to regain full control of the luminaire Move will need to be enabled after testing Note When setting the Move o...

Page 90: ...tests 1 Press Menu 2 Press Up Down arrows until TEST appears Press Enter 3 Use Up Down arrows to select a parameter to test Refer to Menu System Functions on page 60 for a complete list of test parame...

Page 91: ...full to closed Dim3 Tests different dimmer moves EDG1 Fast edge test from min to max EDG2 Slow edge test from min to max FG1 Fixed gobo test Steps through every gobo performs a max forward spin and a...

Page 92: ...0 0 0 0 0 0 7 7 P T only 0 0 0 0 0 0 0 0 255 255 0 7 7 P T only 65535 65535 0 0 0 0 0 0 255 255 0 7 7 P T only 45167 27000 255 35 35 255 0 0 85 0 0 0 2 45167 27000 255 143 143 255 0 0 85 0 11 0 2 451...

Page 93: ...0 35 255 255 0 255 0 0 0 4 45167 27000 100 161 255 255 0 0 85 0 0 0 3 45167 27000 200 216 161 255 0 0 85 0 0 0 3 45167 27000 100 71 216 255 0 0 85 0 0 0 3 45167 27000 200 255 71 255 0 0 85 0 0 0 2 PT...

Page 94: ...45167 0 0 0 0 0 0 0 0 0 0 0 2 2 45167 65535 0 0 0 0 0 0 0 0 0 0 2 2 Tlt2 45167 0 0 0 0 0 0 0 0 0 0 4 5 4 5 45167 65535 0 0 0 0 0 0 0 0 0 4 5 4 5 Tlt3 45167 32767 0 0 0 0 0 0 0 0 0 0 1 2 45167 11207 0...

Page 95: ...0 0 0 5 45167 27000 50 0 0 0 0 0 0 0 0 0 0 5 45167 27000 40 0 0 0 0 0 0 0 0 0 0 5 45167 27000 60 0 0 0 0 0 0 0 0 0 0 5 45167 27000 0 0 0 0 0 0 0 0 0 0 0 5 Str 45167 27000 0 0 0 0 0 0 0 0 0 0 1 45167 2...

Page 96: ...0 0 0 1 45167 27000 0 197 0 0 0 0 0 0 0 0 1 45167 27000 0 216 0 0 0 0 0 0 0 0 1 65 45167 27000 0 179 0 0 0 0 0 0 0 0 1 45167 27000 0 255 0 0 0 0 0 0 0 0 1 9 Cwl2 45167 27000 0 255 0 0 0 0 0 0 0 0 1 9...

Page 97: ...0 0 197 255 0 0 85 0 0 0 1 45167 27000 0 0 216 255 0 0 85 0 0 0 1 65 45167 27000 0 0 179 255 0 0 85 0 0 0 1 45167 27000 0 0 255 255 0 0 85 0 0 0 1 9 FG 2 45167 27000 0 0 255 255 0 0 85 0 0 0 1 9 4516...

Page 98: ...0 0 153 255 0 0 0 0 3 45167 27000 0 0 0 0 153 175 0 0 0 0 2 45167 27000 0 0 0 0 153 216 0 0 0 0 4 45167 27000 0 0 0 0 153 232 0 0 0 0 1 45167 27000 0 0 0 0 153 230 0 0 0 0 4 45167 27000 0 0 0 0 153 23...

Page 99: ...0 85 0 0 0 3 45167 27000 0 0 17 0 0 0 85 128 0 0 2 45167 27000 0 0 17 0 0 0 85 0 0 0 2 45167 27000 0 0 17 0 0 0 85 255 0 0 3 45167 27000 0 0 17 0 0 0 85 128 0 0 2 45167 27000 0 0 17 0 0 0 85 255 0 0...

Page 100: ...VARI LITE VL2200 SERIES SPOT LUMINAIRE USER S MANUAL 84 22 May 01 02 9673 0001 A This page intentionally blank...

Page 101: ...e This appendix provides instructions for troubleshooting and performing routine maintenance which may be necessary during the life of the luminaire Troubleshooting Routine Maintenance WARNING All mai...

Page 102: ...VARI LITE VL2200 SERIES SPOT LUMINAIRE USER S MANUAL 86 22 May 01 02 9673 0001 A This page intentionally blank...

Page 103: ...oke and head covers can be removed to check for loose connectors or obvious signs of wiring component subassembly power supply or PCB printed circuit board failure Connectors can be removed and reinst...

Page 104: ...Display Description Possible Cause and Remedy B1M1 Whl2 NoSn Aux Board 1 Motor 1 Wheel 2 Sensor Not Found Wheel 2 power not connected motor not moving Connect wheel 2 motor power at motor Wheel 2 sens...

Page 105: ...r at motor Dimmer blade not installed on motor shaft Install dimmer blade on motor shaft B1M3 Whl1 NoSn Aux Board 1 Motor 3 Wheel 1 Sensor Not Found Wheel 1 power not connected motor not moving Connec...

Page 106: ...tive Rotating gobo wheel power not connected and rotating gobo wheel aligned with sensor Connect rotating gobo wheel power at motor B2M2 Indx NoSn Aux Board 2 Motor 2 Rotating Gobo Index Sensor Not Fo...

Page 107: ...connector J5 to either aux board Jumper bridge connector J1 between aux boards not connected Install jumper bridge connector J1 between aux boards LAMP STRK FAIL Lamp Strike Failure Lamp failed to st...

Page 108: ...LT NO SENS Tilt Sensor Not Found EOT flag attached to large pulley is not engaging the EOT sensor Ensure flag is attached to the large pulley Ensure that flag passes through the sensor at a depth suff...

Page 109: ...Watt Short Arc Lamp Vari Lite part 71 2528 0700 VL2202 Tools Screwdriver slotted Cotton gloves To replace lamp 1 Remove power from luminaire WARNING Lamps will be extremely HOT after operation Allow l...

Page 110: ...in socket and parallel to guide rods Lamp can be damaged when inserted through reflector if not parallel to guide rods 6 Align guide rods in guide holes and slide backcap into head assembly Re tighten...

Page 111: ...river Phillips 2 Cotton gloves To remove and replace a color filter 1 Remove power from luminaire 2 At removable cover using 2 Phillips screwdriver turn two captive screws one quarter turn and remove...

Page 112: ...r turn and slide bulkhead upward Disconnect motor connections as necessary 3 Rotate wheel until required color filter is accessible at finger access cutout CAUTION Do not touch color filters with bare...

Page 113: ...driver Phillips 2 Cotton gloves To remove and replace a fixed wheel gobo 1 Remove power from luminaire 2 At removable cover using 2 Phillips screwdriver turn two captive screws one quarter turn and re...

Page 114: ...and slide bulkhead upward Disconnect motor connections as necessary 3 Rotate wheel until required gobo is accessible at finger access cutout CAUTION Do not touch gobos with bare fingers Wear cotton g...

Page 115: ...ce a rotating gobo 1 Remove power from luminaire 2 At removable cover using 2 Phillips screwdriver turn two captive screws one quarter turn and remove cover It will remain attached by tether and lamp...

Page 116: ...ION Do not touch gobos with bare fingers Wear cotton gloves or other covering while replacing Clean with glass cleaner and soft cloth if required 5 Remove gobo 6 Aligning flat side correctly and orien...

Page 117: ...ING Remove power from luminaire before performing maintenance The front lens color filters and gobos may require cleaning after extended use A common glass cleaner can be used along with a soft lint f...

Page 118: ...VARI LITE VL2200 SERIES SPOT LUMINAIRE USER S MANUAL 102 22 May 01 02 9673 0001 A This page intentionally blank...

Page 119: ...obo wheel with five rotatable indexable gobo positions and one open position Zoom Optics Zoom angle of 2 8 to one Continuously variable field angle from 13 to 35 VL2201 or 19 to 43 VL2202 Programmable...

Page 120: ...VL2201 Flat field design VL2202 Operational Power Requirements All VL2200 models are powered through standard AC power distribution and require three amps to twelve amps depending on the AC supply vol...

Page 121: ...to determine coverage To calculate Illuminance I at a specific distance D LENS CANDELA cd BEAM ANGLE degrees BEAM DIAMETER TN FIELD ANGLE degrees FIELD DIAMETER TN NFOV Peak Field 556 000 5 0 087 13 0...

Page 122: ...VARI LITE VL2200 SERIES SPOT LUMINAIRE USER S MANUAL 106 22 May 01 02 9673 0001 A This page intentionally blank...

Page 123: ...32 Plastic Road Case Two Hole 22 9620 0194 99 Series 200 Safety Cable 23 9623 0177 DMX Termination Male Connector Assembly 25 9661 0056 Loopback Connector Assembly 25 9661 0057 DMX Termination Female...

Page 124: ...VARI LITE VL2200 SERIES SPOT LUMINAIRE USER S MANUAL 108 22 May 01 02 9673 0001 A This page intentionally blank...

Page 125: ...____ Fixture Serial Number ___________________________________________________________ Equipment Type _______________________________________________________________ Assembly _________________________...

Reviews: