12 Maintenance and Troubleshooting
Varec, Inc.
137
8. Press Enter to open Display Only.
9. Press Minus multiple times to highlight Temperature. The level displays in the units set as
Level Display Units.
10. If necessary, you may need to change the temperature units on the LCD display by doing
the following:
a. Press Enter to access the Main Menu.
b. Press Minus to highlight Basic Setup.
c. Press Enter to open the Basic Setup Menu.
d. Press Minus to highlight Config Params.
e. Press enter to open Config Params menu.
f.
Press Minus to highlight Temp Display Units.
g. Press Enter to open Temp Display Units.
h. Select the appropriate units of measure by using Minus or Plus to highlight and Enter
to accept the selection.
Note
The Temp Display Units changes only the units displayed on the 2920 FTT gauge.
This setting does not change the units that are communicated to the host system.
11. Reconnect the RTD wires to the terminal block.
12. Replace the cover on the junction box.
Random Key Presses when Replacing the Display Cover
When replacing the display cover with power applied to the 2920, you may see what appears
to be random key presses. This is due to the touch keys recalibrating when the cover is
replaced.
To prevent these random key presses, disconnect power from the unit prior to replacing the
display cover. When power is reapplied, the unit automatically re-calibrates to compensate for
the cover glass.
Summary of Contents for 2920
Page 2: ......
Page 16: ...2920 Float Tape Transmitter 1 Introduction 6 Installation and Operations Manual...
Page 114: ...2920 Float Tape Transmitter 6 Bi Phase Mark 104 Installation and Operations Manual...
Page 120: ...2920 Float Tape Transmitter 7 MODBUS 110 Installation and Operations Manual...
Page 126: ...2920 Float Tape Transmitter 9 L J TankWay 116 Installation and Operations Manual...
Page 158: ...2920 Float Tape Transmitter 14 Ordering Information 148 Installation and Operations Manual...
Page 193: ......