12 Maintenance and Troubleshooting
Varec, Inc.
135
To Reset the 2920 FTT Using the Display Interface
1. Press Enter to open the Main Menu.
2. Press Enter to open the System Data menu.
3. Press Minus one time to highlight the Commands menu.
4. Press Minus multiple times to locate the Reset Cmd.
5. Press Enter to open the Reset Cmd. The default command is No action.
6. Press Minus multiple times to highlight Factory Reset.
7. Press Enter to reset the 2920 FTT to factory settings.
The following procedure initializes the 2920 FTT to the factory default settings using the Reset
switch.
To Reset the 2920 FTT with the Reset Switch
Warning!
Obtain a hot permit before removing the transmitter cover with the power
applied.
1. Remove the 2920 FTT cover.
2. Set SW1 (Switch1) in the ON position.
3. Press and release the RESET switch (SW2).
4. Set SW1 (Switch1) to the OFF position.
Resetting the 2920 FTT
The software reset, when executed, does not change any of the values previously set in the
2920 FTT, but has the effect of stopping all processes and restarting them, similar to a
computer reboot.
To perform a soft reset:
1. Press Enter to open the Main Menu.
2. Press Enter to open the System Data menu.
3. Press Minus one time to highlight the Commands menu.
4. Press Minus multiple times to locate the Reset Cmd.
5. Press Enter to open the Reset Cmd. The default command is No action.
6. Press Minus multiple times to highlight Software Reset.
7. Press Enter to reset the 2920 FTT.
Summary of Contents for 2920
Page 2: ......
Page 16: ...2920 Float Tape Transmitter 1 Introduction 6 Installation and Operations Manual...
Page 114: ...2920 Float Tape Transmitter 6 Bi Phase Mark 104 Installation and Operations Manual...
Page 120: ...2920 Float Tape Transmitter 7 MODBUS 110 Installation and Operations Manual...
Page 126: ...2920 Float Tape Transmitter 9 L J TankWay 116 Installation and Operations Manual...
Page 158: ...2920 Float Tape Transmitter 14 Ordering Information 148 Installation and Operations Manual...
Page 193: ......