background image

4. Setup 

Attach 6b unit to the light source. (FIGS 1 

& 2) 

The 6b requires a 7.5”gel frame slot or VaporFlame 
Mounting Adapter. (Sold Separately.)

1. The bottom edge of the 6b unit slides into the standard 

gel frame slot such as on a standard 6” Leko or many 
LED Par fixtures. (outside dimensions of a standard 6 
inch frame are 7.5” x 7.5”). 

FIG. 1

2. Slide the edges of the 6b chassis all the way into the gel 

frame slot.

-OR- 

1. Attach the VaporFlame Mounting Adapter to the face of 

your lighting unit using appropriate screws. 

FIG. 2

2. Attach the VaporFlame chassis to the Mounting Adapter 

using pan-head screws and safety nuts

3. NOTE: VaporFlame Mounting Adapter will only fit 

SELECTED units

Connect Power and Data to the 6b. (FIG 3) 

1. The 6b is powered by the included PowerCON True1 

connector.

2. “Data In” and “Data Through” are via the 5 pin DMX 

connectors.

3. Align the notches on the connector with the notches on 

the unit’s power port, push in and turn clockwise until 
the connector clicks into place.

4. The 6b requires an input voltage of 100-240 VAC.

5. The 6b draws 2.5 amps @110 VAC.

Page   of 

7

12

Rev. 2.0 11/20

FIG. 2

FIG. 3

FIG. 1

Summary of Contents for VF6b

Page 1: ...VF6b Manual Page of 1 12 Rev 2 0 11 20...

Page 2: ...h 6b unit to the light source FIGS 1 2 7 Connect Power and Data to the 6b FIG 3 7 Set the DMX address FIG 4 8 Set Initial Air Water Ratio FIG 5 8 Connect air water supply FIG 6 8 Power the lighting fi...

Page 3: ...dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch The VaporFlame 6b requires an input voltage of 100 240 VAC and has an internal auto switching power supply B...

Page 4: ...ventilation DO NOT place objects directly in the main e ect plume as they may get wet The main plume is described as the part of the e ect closest to the nozzle tip where the water has yet to atomize...

Page 5: ...Page of 5 12 Rev 2 0 11 20...

Page 6: ...mounted at any angle No heat or flammable material makes the VaporFlame safe to use in close proximity to artists gear and scenic pieces The VF6b takes 2 channels of DMX for individual control of the...

Page 7: ...he face of your lighting unit using appropriate screws FIG 2 2 Attach the VaporFlame chassis to the Mounting Adapter using pan head screws and safety nuts 3 NOTE VaporFlame Mounting Adapter will only...

Page 8: ...6b 3 Firmly seat the connectors until they click and lock into place 4 Air supplied to the unit should be dry and free from air compressor condensation 5 NOTE Do not cross the streams Air and water s...

Page 9: ...er thicker e ect but could cause water to collect on surrounding area 6 NOTE Due to di erences in relative humidity the e ect may need to be adjusted for more or less water Nozzles FIG 8 1 Nozzle tips...

Page 10: ...ilding pressure as is supplied to a sink or faucet is fine Unpleasant odors can occur if water is left in the unit for extended periods of time IMMEDIATELY clean the unit if found odors are present We...

Page 11: ...ship back to owner at VaporFlame s expense If VaporFlame determines the fixture is not under warranty VaporFlame will ship the fixture back to the owner at the owners expense If VaporFlame determines...

Page 12: ...nd water hoses are correctly connected to an air and water supply 4 Pinch your fingers over the nozzle tip sealing the output of air and then release This can equalize internal pressure blockages 5 Re...