LifeStar      Owner’s Manual                                                               - 9 - 

Inverter Lamp Description 

 

Inverter 

Light Action 

Description 

 

Steady Green Light 

Inverter in On and Operating. 

Single Blink Green Light 

Inverter circuit is in Stand-by, Shore power is On and supplying AC power to the 
AC loads. The Inverter will turn On and supply the load if shore power is lost. 

Double Blink Green Light 

Inverter circuit is in load Demand. Shore power is Off. The inverter is waiting for a 
load greater than 20 watts. 

Battery Low 

Light Action 

Description 

 

Solid Red 

Inverter is On and the battery is almost too low to operate the inverter. 

Blinking Red 

The  inverter  is  Off.  The  battery  voltage  dropped  below  10.5  volts  DC  and  the 
inverter shut itself Off. The inverter On/Off switch must be cycled to reset the unit. 

Overtemp 

Light Action 

Description 

 

Solid Red 

The  unit  is  Off.  The  unit  has  turned  itself  Off  because  it is  too  hot.  This  can be 
caused  by  operating  an  AC  load  which  is  too  large  for  the  inverter,  or  lack  of 
ventilation. When the unit cools the inverter will start operating again. 

Overload 

Light Action 

Description 

 

Blinking Red 

The inverter is On but overloaded. Reduce the AC load quickly or the inverter will 
shut off due to the overload condition. 

Solid Red 

The  inverter  is  Off.  An  overload  has  occurred  and  the  inverter  has  shut  off  to 
protect  itself.  Reduce  the  AC load,  the  inverter  On/Off  switch must  be cycled to 
reset the unit. 

Charger 

Bulk Absorption 

Light Action 

Description 

 

Blinking Yellow 

The  charger  is  operating.  The  batteries  were  low  and  in  need  of  a charge.  The 
charger  is  in  the  process  of  charging  the  batteries  to  the  bulk  voltage.  The 
charging current is limited based on the position of the Charger High/Low switch. 

Charger 

Ready/Maint. 

Light Action 

Description 

 

Solid Green 

The charger is operating. The batteries are near full charge and the charger is in 
the maintenance mode.  In  this  stage,  the charger  is  holding  the  batteries  at  the 
float voltage. The charging current is limited based on the position of the Charger 
High/Low switch. 

 

Summary of Contents for LIFESTAR 20-1000TUL-DC

Page 1: ...VANNERIncorporated Owner s Manual LifeStar Owner s Manual 1 LifeStar Ambulance Power Module Model 20 1050CUL DC 20 1000TUL DC...

Page 2: ...ity 4 Inverter Function 4 Battery Charger 5 DC Power Output 5 Section 4 Specifications 6 Unpacking the Ambulance Power Module 7 Installing the Ambulance Power Module 7 Inverter Lamp Description 9 Sect...

Page 3: ...VANNERIncorporated Owner s Manual LifeStar Owner s Manual 3 Section 1 General Installation Diagram...

Page 4: ...t Circuit Interrupter GFCI for AC output This enables you to plug AC loads directly into the inverter The DC cables have quick connectors to facilitate installation and pre wiring of emergency vehicle...

Page 5: ...switch labeled IGNITION to the ON position Connect the 12v remote control signal wire to the compression terminal labeled IGNITION To activate GROUND control set the dip switch labeled REMOTE to the...

Page 6: ...k Voltage 14 2 VDC flooded 14 1 VDC gel N A Float Voltage 13 2 VDC flooded 13 6 VDC gel N A Bypass Transfer Output Current GFCI Outlet 12 Amps DC Source Output Voltage Battery Voltage Output Current 2...

Page 7: ...en the battery and inverter within 18 in of the battery or DC wiring bus system Vanner recommends using Bussmann ANN 150 Fuse and 4164 Fuse Holder Vanner P N 014838 Fuse and 03637 Holder or Feraz Shaw...

Page 8: ...on terminal labeled IGNITION To activate GROUND control set the dip switch labeled REMOTE to the ON position Connect the GROUND control signal wire to the compression terminal labeled REMOTE If no rem...

Page 9: ...ed by operating an AC load which is too large for the inverter or lack of ventilation When the unit cools the inverter will start operating again Overload Light Action Description Blinking Red The inv...

Page 10: ...lt LED indicator shows problems such as over temperature output overload or low battery The panels have a gasket seal which will keep the electronics safe from weather and water spray Each panel is eq...

Page 11: ...shop light or drill Verify operation Step 5 Apply shore power Turn vehicle off apply shore power to the 20 1050CUL DC Ambulance shore line connection After shore power has been connected one of the C...

Page 12: ...page 6 Check battery connections if utility power is OFF Check DC fuses if utility power is OFF SYMPTOM ON lamp fully illuminates AC load does not run SOLUTION Check and reset circuit breaker Check a...

Page 13: ...VANNERIncorporated Owner s Manual LifeStar Owner s Manual 13 Notes...