TS
−
I Special servo drive for hybrid electro-hydraulic system of injection molding machine User Manual
Chapter 5 Alarm and diagnosis of servo drive
57
Failure
No.
Failure
code
Failure description
Potential causes
Solutions
24
E.EEP
EEPROM failure
EEPROM reading and writing failure
Seek for technical support
Loose connection of connectors inside
the drive
Ask professional technicians to
maintain
25
E.dL3
Relay contact failure
The power-on buffer circuit is faulty
Seek for technical support
Ambient under temperature
Check whether the ambient
temperature complies with the
requirements
26 E.dL2
Temperature sensor
taking sample anomaly
The temperature sampling circuit
inside the drive is faulty
Seek for technical support
Encoder connection is incorrect
Change the encoder cable
Encoder has no signal output
Check whether the encoder and
Encoder cable disconnection
Reconnect
27 E.dL1
Encoder cable
disconnection
Abnormal function code setting
Confirm that the relevant
+10V power overload
In10V power load
impedance
Utilize externally independent
power supply
+10V power supply and GND is short
circuited
Eliminate the short circuit failure
28 E.P10
+10V power output
abnormal
+10V power terminal circuit failure
Seek for technical support
Too high analog input voltage
Check whether the analog input
voltage complies with the
requirements
Analog input circuit failure
Seek for technical support
29 E.AIF
Analog
input
abnormal
Analog input circuit signal interfered
Increase the P6.22 and P6.24 AI
filtering time
The motor temperature signal reaches
the alarm setting value
Strengthen ventilation and heat
dissipation
Thermistor resistance failure
Check the thermistor
30 E.Ptc
Motor over temperature
(
PTC/KTY
)
The sensor protection threshold of the
motor is set improperly
Adjust the sensor protection
threshold of the motor
The communication of operation panel
RS485 is disconnected
Check the connection of the
equipment communications
Communication failure of operation
panel RS485
Check whether the data
receiving and transmission
complies with the protocol,
whether the check sum is correct
and whether the receiving and
transmission interval complies
with the requirements
31 E.SE1
Communication
abnormal 1
(Operation panel 485)
The drive is set to master mode
Set the drive to slave mode
The communication of RS485 terminal
is disconnected
Check the connection of the
equipment communications
T he baud rate is set improperly
Set compatible baud rate
32 E.SE2
Communication
abnormal 2
(RS485 terminal)
The communication of RS485 terminal
is faulty
Check whether the data
receiving and transmission
complies with the protocol,
whether the check sum is correct
and whether the receiving and
transmission interval complies
Summary of Contents for TS-I Series