TS
−
I Special servo drive for hybrid electro-hydraulic system of injection molding machine User Manual
Chapter 4 Parameters and debugging of servo drive
51
Function
code
number
Function code name
Factory
setting
Setting range
Unit
Prop
erty
Function code selection
User
setting
H0.14
Adjustment coefficient for
30kgf/cm2 reference pressure
21
.
4 0.0
~
160.0 /
○
H0.15
Adjustment coefficient for
20kgf/cm2 reference pressure
14
.
3 0.0
~
160.0 /
○
H0.16
Adjustment coefficient for
10kgf/cm2 reference pressure
7
.
1
0.0
~
160.0 /
○
H0.17
Adjustment coefficient for
0kgf/cm2 reference pressure
0.0 0.0
~
160.0 /
○
H1 Group Multi-section linear marking parameters for reference flow (speed)
H1.00
Adjustment coefficient 100%
reference flow
100.0
0.0
~
160.0 /
○
H1.01
Adjustment coefficient 90%
reference flow
90.0
0.0
~
160.0 /
○
H1.02
Adjustment coefficient 80%
reference flow
80.0
0.0
~
160.0 /
○
H1.03
Adjustment coefficient 70%
reference flow
70.0
0.0
~
160.0 /
○
H1.04
Adjustment coefficient 60%
reference flow
60.0
0.0
~
160.0 /
○
H1.05
Adjustment coefficient 50%
reference flow
50.0
0.0
~
160.0 /
○
H1.06
Adjustment coefficient 40%
reference flow
40.0
0.0
~
160.0 /
○
H1.07
Adjustment coefficient 30%
reference flow
30.0
0.0
~
160.0 /
○
H1.08
Adjustment coefficient 20%
reference flow
20.0
0.0
~
160.0 /
○
H1.09
Adjustment coefficient 10%
reference flow
10.0
0.0
~
160.0 /
○
H1.10
Adjustment coefficient 0%
reference flow
0.0 0.0
~
160.0 /
○
Summary of Contents for TS-I Series