TS
−
I Special servo drive for hybrid electro-hydraulic system of injection molding machine User Manual
50
Chapter 4 Parameters and debugging of servo drive
Function
code
number
Function code name
Factory
setting
Setting range
Unit
Prop
erty
Function code selection
User
setting
d2.02
AI1 percentage after curvilinear
transformation
0 0
~
100.0 %
*
d2.03
AI2 percentage after curvilinear
transformation
0 0
~
100.0 %
*
d2.04
AI3 percentage after curvilinear
transformation
0 0
~
100.0 %
*
d2.05
DI percentage after curvilinear
transformation
0 0
~
100.0% % *
d2.06
Operation panel
∧
/
∨
digital
adjustment value
0 0
~
65535 /
*
d2.07
Terminal UP/DN digital
adjustment volume
0 0
~
65535 /
*
d2.07 Reserved
50984
0
~
65535 /
*
d2.09 Input status display of X terminal
0
0
~
65535 /
*
d2.10 Reference voltage 1 (percentage)
0
0
~
65535 %
*
d2.11 Reference voltage 2 (percentage)
0
0
~
65535 %
*
d2.12
AI failure source display(read
only)
0
/
*
d2.13 Temperature of heatsink 1
0
/
*
H0 Group Multi-section linear marking parameters for reference pressure
H0.00
Adjustment coefficient for
170kgf/cm2 reference pressure
100
.
0
0.0
~
160.0 /
○
H0.01
Adjustment coefficient for
160kgf/cm2 reference pressure
100
.
0
0.0
~
160.0 /
○
H0.02
Adjustment coefficient for
150kgf/cm2 reference pressure
100
.
0
0.0
~
160.0 /
○
H0.03
Adjustment coefficient for
140kgf/cm2 reference pressure
100
.
0
0.0
~
160.0 /
○
H0.04
Adjustment coefficient for
130kgf/cm2 reference pressure
92
.
8
0.0
~
160.0 /
○
H0.05
Adjustment coefficient for
120kgf/cm2 reference pressure
85
.
7
0.0
~
160.0 /
○
H0.06
Adjustment coefficient for
110kgf/cm2 reference pressure
78
.
5
0.0
~
160.0 /
○
H0.07
Adjustment coefficient for
100kgf/cm2 reference pressure
71
.
4
0.0
~
160.0 /
○
H0.08
Adjustment coefficient for
90kgf/cm2 reference pressure
64
.
3
0.0
~
160.0 /
○
H0.09
Adjustment coefficient for
80kgf/cm2 reference pressure
57
.
1
0.0
~
160.0 /
○
H0.10
Adjustment coefficient for
70kgf/cm2 reference pressure
50
.
0
0.0
~
160.0 /
○
H0.11
Adjustment coefficient for
60kgf/cm2 reference pressure
42
.
8
0.0
~
160.0 /
○
H0.12
Adjustment coefficient for
50kgf/cm2 reference pressure
35
.
7 0.0
~
160.0 /
○
H0.13
Adjustment coefficient for
40kgf/cm2 reference pressure
28
.
5 0.0
~
160.0 /
○