TS
−
I Special servo drive for hybrid electro-hydraulic system of injection molding machine User Manual
Chapter 4 Parameters and debugging of servo drive
39
Chapter 4 Parameters and debugging of servo drive
Meanings of Each Item in Function Code Parameter Table
Item
M e a n i n g s
Function code number
The number of function code, such as P0.00
Function code name
The name of function code, which explains the function code’s meanings.
Factory setting
Restore the settings of the function code after the drive is delivered (see P0.01).
Setting range
The value from minimum value to maximum value that can be set to this function code.
Unit
V: Voltage; A: Current; ºC: Celsius degree;
Ω
: Ohm; mH: Milli-henry; rpm: Rotating speed; %:
Percentage; bps: baud rate; Hz, kHz: Frequency; ms, s, min, h, kh: Time; kW: Power; /: No unit
Property
○
: This function code can be changed during operation; ×: This function code can only be changed
during stopping process; *: The setting of this function code is read-only and cannot be changed.
Function code
selection
Function code parameter setting list
User setting
Used for recording parameters by user
4.1 List of Basic Menu Function Codes
Function
code
number
Function code name
Factory
setting
Setting range
Unit
Prop
erty
Function code selection
User
setting
Group P0 Basic Function Parameter
P0.00 User
password
0000
0
~
FFFF
/
○
0000: No password;
Other: Password protection
P0.01 Function code protection
0
0
~
5
/
×
0: All the parameters can be
modified;
1: All the parameters cannot be
modified;
2: Restore parameters in zone P to
factory settings;
3: Restore parameters in zone P to
factory settings; (except for P9
group)
4: Recover the parameters in zone P
and zone A to factory settings;
5: Recover all the parameters to
factory settings. (except for d group)
P0.02 Function code display
0
0
~
3
/
○
0: Basic menu mode
1: Fast menu mode
2: Menu mode of non-leave-factory
setting value function codes;
3: Menu mode of last changed 10
function codes;
P0.03 Oil pressure control mode
1 0
~
1
/
×
0: Non oil control
1: Oil control mode
P0.04
Method of issuing speed (flow)
command
1
0
~
5 /
×
0: Issue via panel(P0.05)
1: Issue via AI3
2: Issue via computer CAN
Summary of Contents for TS-I Series