TS
−
I Special servo drive for hybrid electro-hydraulic system of injection molding machine User Manual
Chapter 3 Digital actuator button, display and motor learning
31
3.4.4 Common Characters Displayed by LED
Except the function codes in first and second level menus, the operation panel will also display the
following characters as shown in the following table:
Prompt
symbol
Meaning
Prompt
symbol
Meaning
8.8.8.8.
Instantaneous display of drive when drive is powered on
LInE
Communication of operating panel fails
−
LU
−
Drive shutdown due to under voltage
LoAd
Drive parameters are being copied and this
symbol will be displayed when parameters are
uploaded to operation panel. For example, set
Pb.23=1
−
dc
−
Drive is in DC braking status
Loc1
Operation panel is locked and the keys are
disabled
−
At
−
Drive is in auto tuning
Loc2
Except M key, other keys are locked
bASE
Basic menu (P0.02=0)
Loc3
Except RUN and STOP/RST keys, other keys
are locked
CoPy
Drive parameters are being downloaded and this symbol
will be displayed when parameters are downloaded to
drive. For example, set Pb.23=2 or 3
ndFt
Non factory setting of function code (P0.02=2)
dEFt
Restore to factory settings (P0.01=2 to 5)
P.CLr
Password is cleared, see 4.5 for password
E.XXX
E. means fault or alarm happens. Analyze the
fault or alarm according to the fault or alarm list in 7.1
P.SEt
Password is set successfully, see 4.5 for
password operation
FASt
Fast menu (P0.02=1)
Prot
Password protection is enabled, see 4.6 for
key locking and unlocking
HoLd
The parameter copy or upload function of operation
panel is disabled
ULoc
Operation panel is identified as key type.
LASt
10 function codes modified recently (P0.02=3)
If the symbol is not listed in the table, please contact the local distributor or our company directly.
Summary of Contents for TS-I Series
Page 1: ...User Manual TS I series servo drive is introdution V T ...
Page 2: ......