TS
−
I Special servo drive for hybrid electro-hydraulic system of injection molding machine User Manual
Chapter 3 Digital actuator button, display and motor learning
29
Structure of first level menu
3.4.2 Format of Second Level Menu
Format of display/set for second level menu
Display/set decimal
:
From data bit 1 to 4, the characters of 0, 1……9 can be displayed or set.
When displayed data >9999, the last bit will be omitted:
For example: When data is 12345, operation panel displays “1234”.
When data is 1234.5, operation panel displays “1234”.
When data is 123.45, operation panel displays “123.4”.
When data is 12.345, operation panel displays “12.34”.
Display/set hex code:
From data bit 1 to 4, the characters of 0, 1……9, A, B, C, D, E and F can be displayed or set.
Meanings of 0. 0. 0. 0. displayed in second level menu
After entering second level menu, besides the displayed data, there are also 4 dots, this means the
password protection and you need to enter the password. The function codes that require password
validation are P0.00
、
A0.00
、
C0.00
、
U0.00
、
U1.00. C area, U0 area and U1 area are factory reserved
parameter area.
Menu structure
Data bit 1
Data bit 2
Decimal point
Data bit 3
Data bit 4