background image

5   Mounting and connecting

5.5 Connecting the cables

Use a pair twisted screened cable (2 pairs + screen), such as Belden 9502. The cables

are connected on the respective indicators. Should an extension cable be used, the

cables are already attached to the connector.

1.

Attach the cables according to the respective indicators on the connector and the

base: A B - +

2.

Snap the connector in place.

3.

Push the cables back.

4.

On the backside of the front there is an EOL jumper used for RS485 bus ter-

mination (see illustration). By default the reader has the termination ON and acts

as the

last

reader on the bus. But if it is an

intermediate

reader on the bus, the

jumper must be removed (or placed in OFF position).

5.

Place the front of the reader with an angle to the hinges at the top of the base.

15

Vanderbilt International (IRL) Ltd.

2017-04-12

Summary of Contents for VR4 S-MF Series

Page 1: ...VR4xS MF VR1xS MF VR10S MF VR11S MF VR40S MF VR41S MF Installation and Mounting Version 9 0 Vanderbilt International IRL Ltd ...

Page 2: ...nd in the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him Document nr A 100224 9 ...

Page 3: ...connecting 9 5 1 Surface mounted reader 10 5 2 Surface mounted reader with cables fed from outside 11 5 3 Back box mounted reader 13 5 4 Back box mounted reader with adapter plate 14 5 5 Connecting the cables 15 5 6 Disassembling the reader 17 6 Default settings 18 7 Connecting card reader to SiPass integrated 19 7 1 Setting the card reader address 19 8 Disposal 21 ...

Page 4: ...ication from neither the reader nor the system they are connected to can be extracted They are made of hardwearing materials and will endure most weather conditions The readers are easy to mount and connect and can be mounted on a flat surface or partly inside a back box They can be cleaned with most kind of domestic detergents All readers have a multicolour light frame The VR40S MF and VR41S MF a...

Page 5: ... to 6 cm Up to 6 cm Indicators 3 x LED red yellow green 1 x Buzzer Multicolor light frame 3 x LED red yellow green 1 x Buzzer Multicolor light frame Keypad No Yes Display No Yes graphic monochrome OLED Operating temperature 40 C to 55 C 40 C to 55 C IP rating IP55 IP55 IK class 08 08 Housing Zinc casted metal bezel with polycarbonate plastic front Zinc casted metal bezel with polycarbonate plastic...

Page 6: ... directives Vanderbilt hereby declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC on Electromagnetic Compatibility EMC The EC Declaration of Conformity is available from your Vanderbilt sales office or Vanderbilt International IRL Ltd Clonshaugh Business and Technology Park Clonshaugh Dublin 17 Ireland 3 2 FCC statement...

Page 7: ...der components 1 Hinge 6 Screw for removal from wall tamper protection 2 Base 7 Front 3 Cord gasket 8 Back box plate 4 Knock outs x 4 9 Adapter plate VR11S MF VR41S MF 5 Tamper base 7 Vanderbilt International IRL Ltd 2017 04 12 ...

Page 8: ...omponents 1 Screws for back box plate 2 Connector 3 Opening tool please note that this is a symbolic depiction of the opening tool 4 Extension cable VR11S MF VR41S MF 8 Vanderbilt International IRL Ltd 2017 04 12 ...

Page 9: ...age for l Surface mounted reader on the next page the reader is mounted on the base which first is fastened on a wall l Surface mounted reader with cables fed from outside on page 11 the reader is mounted on the base and the cables are connected via one of the knock outs l Back box mounted reader on page 13 the reader is partly mounted inside a back box in a wall The two extra screws prevent the r...

Page 10: ...ll be pushed through this hole 2 Attach the base to the wall with three screws one in the middle at the top of the base and two in the corners at the bottom of the base 3 In case that the removal from wall tamper protection is required fix the screw into the hole under the tamper base Ensure to not use excessive force since this can damage the tamper base 4 Continue to follow the instructions Conn...

Page 11: ... the knock outs the cables should be fed through 3 Insert the flat head screw driver in the pocket of the knock out 4 Hammer the screw driver handle This will create enough pressure to crack the exact area of the base which will release the knock out 5 Tilt the knock out with the screwdriver 6 Pull the knock out away from the base 11 Vanderbilt International IRL Ltd 2017 04 12 ...

Page 12: ... fix the screw into the hole under the tamper base Ensure to not use excessive force since this can damage the tamper base 9 Feed the cables through the opening and reinsert the cord gasket Proceed to the instructions for Connecting the cables on page 15 It is recommended to seal the gap which the knock out creates Please note that a reader with a removed knock out is not IP 55 12 Vanderbilt Inter...

Page 13: ...ch the extra screws at the lower part of the back box plate in order to prevent rotation Use only the screws included in the packet for the lower part of the base since those ensure that the reader front will fit perfectly to be securely fitted over the back box 3 Continue to follow the instructions for Connecting the cables on page 15 13 Vanderbilt International IRL Ltd 2017 04 12 ...

Page 14: ...ce the back box plate on top of the adapter plate 2 Attach the base and adapter plate with two screws on the side 3 Continue to follow the instructions for Connecting the cables on the facing page The adapter plate is to be used for square back boxes which measure 70 mm x 70 mm The adapter plate is used for common UK square boxes 14 Vanderbilt International IRL Ltd 2017 04 12 ...

Page 15: ...icators on the connector and the base A B 2 Snap the connector in place 3 Push the cables back 4 On the backside of the front there is an EOL jumper used for RS485 bus ter mination see illustration By default the reader has the termination ON and acts as the last reader on the bus But if it is an intermediate reader on the bus the jumper must be removed or placed in OFF position 5 Place the front ...

Page 16: ...5 Mounting and connecting 6 Fold the front down until the snap lock confirms a secure attachment 16 Vanderbilt International IRL Ltd 2017 04 12 ...

Page 17: ...fully insert the opening tool in the slot between the base and the front 2 Push gently and lift the front of the base To remove the connector 1 Insert the opening tool as indicated on the picture 2 Push down gently and tilt the connector away from the base 17 Vanderbilt International IRL Ltd 2017 04 12 ...

Page 18: ...ivation are possible Buzzer volume for key press 2 Buzzer volume for card read 2 System sound 10 Light frame follows LED indicators Red yellow green Reading MIFARE Classic UID Reading MIFARE Plus SL1 SL3 UID Reading MIFARE DESFire EV1 UID The card readers are delivered in this default mode This mode can be altered with the Configuration Card Creation Tool 3CT which enables for required settings to...

Page 19: ...o a RIM DRI ERI the card reader and bus address is automatically configured as follows 1 The first powered up card reader gets bus address 1 2 The secondly powered up card reader gets bus address 2 and so forth When the card reader is first powered the yellow LED flashes The flashing lights stop when it is correctly configured to SiPass integrated This can be tested by holding a card in close prox...

Page 20: ...7 Connecting card reader to SiPass integrated 20 Vanderbilt International IRL Ltd 2017 04 12 ...

Page 21: ...ed by the European Directive 2002 96 EC The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health It is a precondition for reuse and recycling of used electrical and electronic equipment For more detailed information about disposal of your old appliance please contact your city office waste disposal ser...

Page 22: ...184 95 114 60 16 85 86 12 5 12 14 42 5 42 2 5 5 Scale 1 1 Units mm ...

Page 23: ......

Page 24: ...ness and Technology Park Clonshaugh Dublin 17 Ireland www vanderbiltindustries com 2017 Copyright by Vanderbilt International IRL Ltd Data and design subject to change without notice Supply subject to availability Document Nr A 100224 9 Edition Date 2017 04 12 ...

Reviews: