Engineer programming via the browser
Panel status
178
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Performable actions
Refresh
Updates the status information displayed for the panel.
Log
Click on the Log button to view a log of the input status of that zone.
Inhibit
Click this button to inhibit a fault or open zone. The inhibit operation will
disable that fault or zone for one arming period only.
Inhibit operation is not available in Security Grade EN 50131 Grade 3.
Restore
Click this button to restore the alarm condition of the panel.
Isolate
Zone . Isolating a zone will deactivate that zone until such time as the zone
is explicitly deisolated again.
It is recommended that you exercise caution when isolating zones as those
zones will not be active every time the system is SET.
Soak
Highlight a zone and click this button to perform a Soak test on that zone.
Seismic Test
Click this button to initiate a test of the selected seismic sensor. For more
information on seismic sensors, see Seismic Sensors [➙ 324].
Hide Closed
Click this button to hide all closed inputs.
Filter Zones
Select a zone type from the dropdown menu. Only the summary of this zone
type will be displayed.
17.6.5
Doors
1. Select Status > Doors.
2. See tables below for further information.
Door
This ID number is a unique identifier for the door.
Zone
The zone number the door position sensor is attached to (only if the door position
sensor input is also used as intrusion zone).
Area
The area the door position sensor input and the card reader are assigned to.
DPS
Status of the door position sensor.
DRS
Status of the door release switch.
Status
The status of the door (OK, fault).
Door Mode
Specifies the door operate mode.
Performable actions
Refresh
Updates the door summary.
Log
Displays a log of events for the selected door.
Lock
Locks the selected door.
Unlock
Unlocks the selected door.
Normal
Returns the door to normal system control.
Momentary
Unlocks the door for one timed interval.
!