Battery protection
Current limited to 1A (fuse protected), deep discharge protection at 10.5V DC
+/- 3%
Software update
Local and remote upgrade for controller, peripherals and GSM/PTSN modems.
Calibration
No calibration checks required (calibrated at manufacturing)
Serviceable parts
No serviceable parts
Operating temperature
-10 to +50°C
Relative humidity
Max. 90% (non condensing)
Colour
RAL 9003 (signal white)
Weight
SPC422x/4320: 4.500kg
Dimensions (W x H x D)
SPC422x/4320: 264 x 357 x 81mm
Housing
SPC4320.320: Small metal housing (1.2mm mild steel)
SPC422x.220: Small housing with metal base (1.2mm mild steel) and plastic lid
Housing can contain up to
SPC422x/4320: 1 additional expander (size 150 x 82mm)
IP rating
30
ATS
3
ATP
8
Event Profiles
5
Event Exceptions
10
Command Profiles
5
1) Max. 400m between devices/cable types IYSTY 2 x 2 x Ø 0.6mm (min.), UTP cat5 (solid core) or
Belden 9829.
2) More I/O expanders can be addressed instead of a keypad or door expander, but number of
programmable inputs/outputs cannot exceed specified system limits.
4.2 SPC5000
Programmable areas
16
Max. number of user PINs
500
Remote controls
Up to 100
PACE Devices
250
Wireless Panic Alarm
Up to 128
Event memory
10,000 intrusion events, 10,000 access events
Number of on-board zones
l
SPC5320/5330 — 8
l
SPC5350 — 16
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Technical Data
© Vanderbilt 2018
33
A6V10276959-d