TLS
Enabled
Tick this box to enable encryption operation on embedded web server. By default
this is enabled. With TLS enabled, web pages can only be accessed by using
‘https://’ prefix before typing the IP address.
Telnet
Enabled
Tick this box to enable the Telnet server. (Default: Enabled)
Note:
Using Telnet without a comprehensive knowledge can damage the
controller configuration; this should only be used if the user has sufficient
knowledge or is being instructed by someone with such knowledge.
Telnet Port
Enter the number of the Telnet port.
SNMP
Enabled
Tick this box to enable Simple Network Management Protocol (SNMP). (Default:
Disabled)
SNMP
Community
Enter the Community ID for the SNMP protocol. (Default : Public)
ENMP
Enabled
Tick this box to enable Enhanced Network Management Protocol (ENMP).
(Default : Enabled in Full Engineer)
ENMP Port
Enter the ENMP port number (default: 1287).
ENMP
password
Enter the password for the ENMP protocol.
ENMP
change
enabled
Check this box to enable network changes to be made with ENMP protocol.
17.11.1.2 Ethernet
The Ethernet port on the controller can be configured from both the browser and keypad interfaces. An
Ethernet connection with the SPC controller can be established using a direct connection or a LAN
connection.
1. Select
Communications > Communications > Ethernet
.
The following page will be displayed.
2. Configure the fields as described in the table below.
IP
address
Enter the IP address of the panel.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser