User/Panel Rights
l
Select the required user rights that are to be assigned to this user profile.
User rights
Right
User
Profile
Type
Default
Description
User Rights - Intruder
Unset
Limited
Standard
Manager
The UNSET operation unsets the alarm. This menu option is only presented on the
keypad after an Entry/Exit zone has been activated and a valid user code has been
entered.
Partset A
Standard
Manager
The PARTSET A option provides perimeter protection to a building while allowing free
movement through the access areas.
Zones that have been classified as EXCLUDE A remain unprotected in this mode. By
default, there is no exit time; the system sets instantly on selection of this mode. An
exit timer can be applied to this mode by enabling the Partset A timed variable.
Partset B
Standard
Manager
The PARTSET B option applies protection to all zones except those that have been
classified as EXCLUDE B.
By default there is no exit time; the system sets instantly on selection of this mode.
An exit timer can be applied to this mode by enabling the Partset B timed variable.
Fullset
Limited
Standard
Manager
The FULLSET operation fully sets the alarm system and provides full protection to a
building (opening of any alarm zones activates the alarm).
On selecting FULLSET, the buzzer sounds and the keypad display counts down the
exit time period. Exit the building before this time period has expired.
When the exit time period has expired, the system is set and opening of entry/exit
zones starts the entry timer. If the system is not Unset before the entry timer expires,
the alarm is activated.
Forceset
Standard
Manager
The FORCESET option is presented on the keypad display when an attempt is made
to set the system while an alarm zone is faulty or still open (the top line of the display
shows the open zone).
Selecting this option sets the alarm and inhibits the zone for that set period.
Delay
Auto Set
Standard*
Manager
User can delay or cancel autosetting.
Restore
Standard
Manager
The RESTORE operation restores an alert condition on the system and clears the
alert message associated with that alert condition.
An alert condition can only be cleared after the zone(s) or fault(s) that triggered the
alert condition have been restored to their normal operating state and the CLEAR
ALERT option in user programming is selected for that zone.
Inhibit
Standard
Manager
Inhibiting a zone deactivates that zone for one alarm set period.
This is the preferred method of deactivating a faulty or open zone as the fault or open
condition is displayed on the keypad each time the system is being set to remind the
user to attend to that zone.