16.16 Isolate
Zones, system alerts or alerts from X-BUS devices can be manually isolated from the keypad. Isolating
a zone removes that zone from the system until the user de-isolates it.
To isolate zones, system alerts or alerts from X-BUS devices:
1. Scroll to ISOLATE and press SELECT.
2. Scroll to the desired option in the table below and press SELECT.
ZONE
Select the required zone and toggle the setting from NOT ISOLATED to
ISOLATED.
SYSTEM
Isolate the desired system alert.
XBUS
Isolate the desired alert from EXPANDERS or KEYPADS:
l
XBUS COMMS LOST
l
XBUS FUSE FAULT (Expanders only)
l
X-BUS TAMPER
VIEW
ISOLATIONS
To view a list of the isolated zones, system alerts and X-BUS devices
alerts.
16.17 Event Log
Recent events on the system are displayed in the EVENT LOG option. Events flash in one second
intervals.
1. Scroll to EVENT LOG and press SELECT.
2. To view an event from a particular date, enter the date with the numeric keys.
The most recent events are displayed on the bottom line of the display. All previous events are
displayed for one second in turn.
16.18 Access Log
Zone access on the system is displayed in the ACCESS LOG option.
1. Scroll to ACCESS LOG and press SELECT.
2. Select a door on the system for which you want to display access events.
The most recent access events are displayed with a date and time.
3. Scroll down through the access events or enter a date and press ENTER to find a particular
access event.
16.19 Alarm Log
The ALARM LOG displays a list of alarm events.
l
Select
Log > System Log > Alarm Log
.
The following types are displayed in this log:
l
Zones
– Alarm
– Panic