Vanderbilt IRCW6-12 Installation Instruction Download Page 1

IRCW6-12

 

Remote Control 
Télécommande

  

STEP:  A6V10327163_b 

Edition: 04.04.2016 

P/N: 7102013 rev. A 

 

 

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

English 

Installation Instruction

 

Before starting to install and work with this device, please read the Safety 
Instructions. 

Battery exchange (fig. 2-4)

 

In order to change the battery, open the housing (Fig. 2) with a screw driver, 
cautiously remove the old battery and replace it with a new one and close the 
housing again (Fig. 3&4). 

Insert the battery in the battery holder making sure the polarity is correct 
(+) (-). 
Risk of explosion if battery is replaced by an incorrect type. 
Clean the remote control only with a soft cloth or sponge moistened lightly 
with a mixture of water and mild detergent and wipe it dry immediately. Also 
never use solvents such as kerosene, acetone or thinner. The use of 
abrasives of any kind is strictly forbidden. 

Enrollment and testing

 

To enrol the IRCW6-12 into the control panel or gateway, follow the instructions 
of the corresponding installation/configuration manual. 
Since IRCW6-12 is supplied with the battery already installed, the unit is 
practically ready to be tested. 

Press a key on the IRCW6-12: verify that the transmit LED lights.

Make sure that the control panel responds as programmed and as stated in
the installation/configuration manual.

Repeat the test at locations where the remote control will be operated under
normal use, in order to ensure the wireless transmission is not blocked by any
walls or large objects, or affected by structural materials.

Technical data

 

Data protocol 

Si2Way 

Functions (fig. 1)

 

Wireless range 

100 m in open space 

Symb.

 

No.

 

Key/Indicator.

 

Description

 

1

 

ARM 

Sends a Set (ARM) command to alarm 
system. 

Frequency band 

868 MHz 

Identification 

Unique ID serial number 

– 24 bit 

2

 

STAY 

Sends a Part Set (STAY) arm command. 

Control transmission 

Arm, Stay, Disarm, Optional Control, Panic 

Power 

Automatic Power Saver 

– Low Bat Indication 

(LED flashing) below 2.4 V 

3

 

DISARM 

Sends an Unset (DISARM) command. 

EMI rejection up to 
2 GHz 

> 10 V / m 

4

 

Additional 
Function 

Activates an assigned function 
(e.g. light, garage, door, etc.). 

5

 

PANIC/SOS 

These two buttons pressed together for 2 
seconds send a PANIC alarm. 

Battery 

Battery Lithium 3 V - type: CR2032 

Current consumption 

Standby: < 1

max.: < 28 mA 

6

 

Indication Light 

Lights up when transmitting, flashes if 
battery is low. 

Environmental conditions: 

Leash insertion (optional, fig. 5-7)

 

Operating temperature 

-10 to +50 °C 

You can clip the leash into a key ring or neck band. 

Storage temperature 

-20 to +60 °C 

Humidity (EN60721) 

< 85 % r.h., non condensing 

Erase previous enrollment

 

Housing protection 
EN60529, EN50102 

IP41 / IK02 

In order to re-enrol an IRCW6-12 into a new control panel you must first erase 

the remote control by pressing at the same time the following keys 
until the indication light blinks fast green/red (~5s) 

EC Declaration of Conformity 

Hereby, Vanderbilt International (IRL) Ltd declares that this radio equipment 
type is in compliance with all relevant EU Directives for CE marking. From 

20/04/2016  it  is  in  compliance  with  Directive  2014/30/EU  (Electromagnetic 
Compatibility  Directive)  and  Directive  2014/35/EU  (Low  Voltage  Directive). 
From 13/06/2016 it is also in compliance with Directive 2014/53/EU (Radio 

Equipment Directive). 
The full text of the EU declaration of conformity is available at: 

http://pcd.vanderbiltindustries.com/doc/wireless.

 

Complies with : 

EN 50130-4:2011; EN 61000-6-3:207/A1:11; EN 301 489-1 

V1.9.2; EN 301 489-3 V1.6.1, EN 300 220-2 V2.4.1, EN 60950-1:2006 + 

A11:2009 + A1:2010 + A12:2011 + A2:2013, EN 62479.

For more detailed instruction please refer to the manuals of the respective 
control panel or gateway. 

Reviews: