background image

INSTALLATION MANUAL 

ES 470

 

Shock and vibration detector

 

DESCRIPTION 

ES  470  offers  reliable  monitoring  against  attacks  with 
mechanical  tools.  The  ES  470  is  a 

s

hock  and  vibration 

detector with 3  separate detection channels: an integra- 
tion  channel /  saw channel for  weak signals with long 
duration, a  counting channel that senses strong impact 
on the monitored surface and an explosion channel 
which senses very strong signals from e.g. an explosion. 

ES 470 has  built-in relays for  the  alarm and tamper 
outputs.  This allows the ES  470 to be connected directly 
to the alarm central unit, this means that no analyzer unit 
is necessary. 

The ES 470 is polarity independent. 

FEATURES 

Relay outputs for alarm and tamper

Polarity independent for easy connection

3 separate detection channels

Cover radius up to 3m

Resistant to interference

Detailed sensitivity setting

Suitable for 24-hour monitoring

DAY and NIGHT control of LED

OPERATING PRINCIPLE 

The ES 470 uses a piezoelectric sensor to monitor the vibration 
signature  of  the  mounting  surface  that  occurs  when  it  is 
crushed  or  cut  with  tools.  The  signal  has  a  special  signature 
with a broad spectrum and high amplitude that the electronics 
detects,  then  opens  the  alarm  relay  and  illuminates      the 
LED.  The  ES  470  has  a  built-in  self-control  and  voltage 
monitoring.  Fault  is  indicated  by  a  flashing  LED  (alarm  relay 
remains  closed).  The  indication  is  controlled  by  a  DAY  and 
NIGHT  function.  With  8Vdc  on  the  power  input,  DAY  mode  is 
active  and  LED  lights  up  at  alarm  and  with  pulsating  shine  in 
case  of  failure.  At  6Vdc,  NIGHT  mode  is  active  and  LED  is 
switched off in case of alarm or fault. 

Resetting the detector after alarm can be done in two different 
ways: 

Disconnect power to the detector

Switch from DAY to NIGHT mode

MOUNTING 

1.

Loosen the screw for the cover and lift it off.

2.

Select the mounting location and mark the mounting holes
with the bottom part as a template.

3.

Drill with a 2-2.5 mm drill for the two supplied mounting
screws.

NOTE!  A  clean  and  smooth  mounting  surface  under  the 
detector provides maximum range. 

CONNECTIONS 

The detector has 6 screw terminals: 

ES470 manual I-200422 

Page 

of 

Function 

DC Input voltage (-) or (+) 

DC Input voltage (-) or (+) 

Alarm output, relay (NC) 

Alarm output, relay (C) 

Tamper output, relay (NC) 

Tamper output, relay (C) 

Reviews: