background image

ACTpro-100 / ACTpro-1002A

Installation and Operating Instructions

Document ID: A-100542-b

Edition date: 15.03.2019

Summary of Contents for ACTpro-1002A

Page 1: ...ACTpro 100 ACTpro 1002A Installation and Operating Instructions Document ID A 100542 b Edition date 15 03 2019...

Page 2: ...at this equipment type is in compliance with the following EU Directives for CE marking Directive 2014 30 EU Electromagnetic Compatibility Directive Directive 2011 65 EU Restriction of the use of cert...

Page 3: ...nstallation 6 2 1 Wiring 6 2 1 1 DIP switch addressing 7 2 1 2 Wiring for Vanderbilt EM1030e Clock Data or Wiegand Reader 8 2 1 3 Wiring exit readers 9 2 2 ACTpro 100 9 2 2 1 Mounting 9 2 2 2 Power su...

Page 4: ...o 50 C 10 to 40 C 75 RH non condensing Dimensions H x W x D mm 165 x 235 x 55 275 x 330 x 80 Weight kg 0 4 2 2 Enclosure Material ABS 1 2mm steel grey powder coated LED Status Indicators Yes Yes PSU F...

Page 5: ...AC Aux relay 400mA 30VDC 400mA 30VDC 1 2 Ordering details ACTpro 100 V54502 C120 A100 Single door station ACTpro 1002A V54502 C121 A100 Single door station with 12V DC 2A PSU 1 3 Monitoring All faults...

Page 6: ...o the controller is disconnected during installation Mains power should be connected by a licensed electrician in accordance with local national codes 2 1 Wiring A Door contact F Vanderbilt reader wir...

Page 7: ...linked to 0V or the feature should be disabled in ACT Enterprise software l The Blue Comms OK LED is on while ACTpro 100 is communicating with the controller l Red Fault LED illuminates on l Tamper l...

Page 8: ...1 2 Wiring for Vanderbilt EM1030e Clock Data or Wiegand Reader Wire Colour Terminal White SENSE Green CLOCK DATA 1 Blue DATA DATA 0 Red 12V Black 0V Brown RED Yellow GREEN ACTpro 100 ACTpro 1002A Ins...

Page 9: ...ing The unit should be installed in a ventilated area that allows for accessibility after installation 2 2 2 Power supply The ACTpro 100 requires an external 12V DC power supply The supply should be c...

Page 10: ...lt recommend that you place the provided ferrite bead a noise suppression device around the power supply cable to attain a desired level of electromagnetic compatibility EMC The ferrite bead is provid...

Page 11: ...batteries continue to supply voltage and current to the load The green Mains LED should be off Note Batteries must have sufficient charge to supply the load 5 Reconnect mains power The green Mains LE...

Page 12: ...rbilt International Ltd Clonshaugh Business and Technology Park Clonshaugh Dublin D17 KV 84 Ireland vanderbiltindustries com contact Vanderbilt 2019 Data and design subject to change without notice Su...