ACT365-ACU
ACT365-ACU2A
ACT365-ACUPoE
PoE 802.3af input (PoE)
N/A
N/A
13.8V at 0.3A 0.5A battery
charge
Battery charging
N/A
Yes
Yes
Standby Battery
N/A
12V 7Ah Battery
12V 7Ah Battery
Battery Deep Discharge
Protection
N/A
No
Yes
Input: Voltage Rated
N/A
100–240V AC
N/A
Input: Voltage Operating
N/A
90–264V AC
N/A
Input: Frequency
N/A
50–60Hz
N/A
Input: Max Current
N/A
1.0A (@ 90V AC)
N/A
Input: Mains input fuse
N/A
T2.0A
N/A
Input: Max standby power
N/A
0.5W (no load and no
battery connected)
N/A
Output: Voltage
N/A
13.4–14.2V DC
(13.8V DC Nominal)
on mains power
10.0–12.3V DC on
battery standby
N/A
Output: Max load current
N/A
2.0A
N/A
Output: Ripple
N/A
150mA pk–pk max
N/A
Output: Load output fuse
N/A
F2.0A
N/A
Output: Overload
N/A
Electronic shutdown
until overload or short
circuit removed
(Under mains power
only)
N/A
1.1.2 Relay load
When used with inductive loads (Maglock/Strike locks) the following ratings apply.
ACT365-ACU
ACT365-ACU2A
ACT365-ACUPoE
Main relay
1.5A @ 30VDC /
1.5A @ 50VAC
1.5A @ 30VDC /
1.5A @ 50VAC
1.5A @ 30VDC /
1.5A @ 50VAC
Aux relay
400mA @ 30VDC
400mA @ 30VDC
400mA @ 30VDC
1.2 Ordering details
ACT365-ACU
V54502-C130-A100
Single door cloud IP controller
ACT365-ACU / ACT365-ACU2A / ACT365-ACUPoE – Installation Instructions