SECTION 4: INSTALLATION
AIR N ARC
®
300 SERIES ALL-IN-ONE POWER SYSTEM
®
PAGE - 46
090034-OP_r0
location of a remote-mounted air tank, consider the
following:
•
Air system piping relation to the 300 Series
machine.
•
Hindrance to any access, or operation of,
other standard or mounted vehicle
system(s), including any under deck, or
accessible wiring, piping, etc.
•
Service output location.
To prepare and install the remote air tank follow these
guidelines:
For compressor discharge piping, use a 3/4" minimum,
S-TW Series hose (that meets SAE 100R14A), extruded
PTFE tube with stainless steel single wire braid. The
working pressure and temperature ratings should be: 200
psi air @ 300°F (similar to PA87939).
4.10 POST-SET UP INITIAL TEST
FUNCTION
Before attempting the post-set up initial test function,
review all of the tasks laid forth in
Sections 4.4
through
TOOLS/ITEMS NEEDED
REPLACEMENT
PART(S)
Air Tank and Mounting Hardware
I
Relief Valve (200 psi) - supplied
CO450008
Discharge Piping (see below)
Wrenches
I
NOTE:
If tank is larger than 6"OD, it must be ASME rated.
NOTE
When determining the location of the air
tank, keep in mind that the drain valve
will need to be accessed on a frequent
(daily) basis.
NOTE
Ensure that the lines do not make contact
with sharp edges, moving parts or
exhaust heat (consult
Appendix A,
Section A.6, Hose Installation Guide
for
assistance in running hose lines).
NOTE
Mounting brackets are available to space
panel off from truck body (
Figure 4-7).
Contact Vanair® for details.
KEY
DESCRIPTION
A
MOUNTING PATTERN WITH
SPACER
(P/N A16738P)
B
MOUNTING PATTERN
WITHOUT SPACER
Figure 4-7: Remote Panel Mounting
Pattern (with and without Spacer)
10.5”
5.0”
0.5Ø
A
10.5”
7.5”
0.5Ø
B