QUICK START GUIDE: Honda EU2000i Generator

+44 (0)1428 661 660

This guide is meant to serve as a quick reference for operating the EU2000i Generator. 

It is for your convenience and is not intended to replace the information found in the Operations Manual provided.

RR135V4_15/02/2016_JO

This generator runs on standard unleaded petrol. This generator has the 

correct specification to run the MP1 pump to 60m – please only use this 

Generator with the Grundfos MP1 pump.

Your generator is transported to you with the correct oil level inside. Tipping 

the generator more than 45 degrees will displace the oil into parts of the 

engine it shouldn’t be in. 

Pre start checks

1.  Check oil level by removing the maintenance cover. Refer to Figure 1 for 

correct level. If the oil level is incorrect contact Van Walt as it indicates oil 

displacement has occurred during transit. 

2.  With engine switch in the OFF position, turn over with the starter a couple 

of times to ensure there is no excessive resistance which may indicate oil 

in the combustion chamber. If in doubt contact Van Walt.

3.  Disconnect all appliances

4.  Ensure eco-throttle is turned off

Figure 1 Location of dipstick and correct oil level 

in generator

Before starting the generator disconnect all appliances.

Starting the Generator

1. 

In a well ventilated area remove the fuel cap in picture 1, fill the 

generator with unleaded petrol & replace fuel cap.

2.  Set vent switch on top of fuel cap in picture 1 to the ‘on’ position.

3.  Turn the engine switch (in picture 2) to ‘on’ position.

4.  Apply Choke (in picture 3) as ambient temperature necessitates. DO 

NOT RUN THE GENERATOR FOR PROLONGED PERIODS WITH THE CHOKE 

ENGAGED AS THIS CAN DAMAGE THE GENERATOR.

5.  Pull starter grip lightly until resistance is felt, then pull briskly (note: Do not 

allow starter grip to snap back against the engine, return it gently to 

prevent damage to starter or housing).

6.  Adjust the choke when the engine is running smoothly.

7.  Allow to run without load for at least 2 minutes
The Eco-throttle should 

NOT

 be used when this generator is used with Van 

Walt Equipment.

Stopping the Generator

1. First unplug all appliances from the generator

2. Turn the engine switch to the ‘off’ position.

3. Allow the engine to cool well then set the vent switch to the ‘off’ position.

Draining the Fuel

BEFORE DRAINING ANY FUEL ENSURE THAT YOU ARE IN A WELL VENTILATED 

AREA AND APPROPRIATE PPE IS WORN

1.  Remove strainer and lock ring from the fuel tank and insert the longer open tube

2. 

Place the bung into the opening of a petrol container - this must be a tight fit for 

the pump to operate (Pic 4)

3.  Put the hand pump into the vacuum setting and apply suction to the system 

(Pic 5)

4.  The tube inside the tank may need moving around to ensure all petrol is 

retreived.

5.  Replace strainer and locking ring

6.  Return the pump to the bag provided.

IMPORTANT NOTE - THIS GENERATOR MUST BE EMPTY OF FUEL BEFORE IT IS 

RETURNED. IF FUEL IS PRESENT IN THE GENERATOR UPON RETURN A DISPOSAL FEE 

WILL BE CHARGED. VAN WALT WILL NOT BE RESPONSIBLE FOR ANY COSTS THAT 

MAY OCCUR FROM SHIPPING THIS GENERATOR CONTAINING FUEL.

Scan to download the video

 

Pic 1

Pic 5

Pic 4

Pic 3

Pic 2

This video shows 

the EU1000i 

Generator. 