Double-acting valve
Type
Directional control valve including Zero leak
Nominal flow capacity
90 l/min
Control
Electrically adjusted CAN-bus valves
•
With joystick
•
Rear valves 1 and 2
•
Front valves 1F and 2F
•
With control levers
•
Rear valves 3, 4 and 5
•
Front valve 3F
Quick couplings
Standard
ISO7241-1 Series A
6.14.3.2 Counter pressure when using the return connection for auxiliary
hydraulics
Flow l/min, temperature
Return connection counter pressure (1 inch)
50 l/min, 60°C
2.5 bar
6.14.4
Rear linkage
Maximum lifting force
Lifting cylinder ø
Lower link type
The length of the lower
links
78 kN
100 mm
Category 3, quick
coupling grabs
960 mm
Function
Linkage version ACB
Linkage version ACD
With electrohydraulic lower link
draft sensing
x
x
Draft control mixing (position
control/draft control mixing)
x
x
Lowering speed, independent of
load
x
x
Transport height
x
x
Drive balance control
x
x
Slip control
–
x
6.14.4.1 Lifting forces and lifting ranges
2
1
3
GUID-75A93C07-46D6-408D-A929-A88571777253
1. Lifting rod's first fastening point
2. Lifting rod's second fastening point (factory setting)
3. Lifting rod's third fastening point
6. Technical specifications
- 501 -
Summary of Contents for Versu N Series