56
Revision D November 2022
8) Check to see that the Diaphragms are in usable condition. Diaphragms which are bowed
or have bent legs must be replaced.
9) Check that the Fender Panels are properly attached with the Mushroom Washer
Assemblies. Damaged Fender Panels and Transition Panels must be replaced.
10) Check the gaps between Fender Panels. The maximum gap allowed for these overlapping
parts (including Fender Panels overlapping panels behind the system) is 3/4” [20 mm] for
narrow systems and
1.00” [25 mm]
for wide systems (p. 53). Ensure the Mushroom
Washer Assemblies are tightened until the nuts make contact with the bolt shank. If the
gaps between the Fender Panels are still too large it may be necessary to replace bent
parts.
11) Replace all crushed Cartridges. Refer to Cartridge Placement on page 37 or 51.
12) Check the torque of all anchor bolts on the system (p. 13).
13) Check to be certain that the site is free from excessive dirt or debris. The QuadGuard
®
HS
system is once again ready for use.
Parts Ordering Procedure
Make a list of all damaged parts using part descriptions shown on page 56.
Circle the appropriate system attributes below. This information is necessary to receive the proper
parts.
System width:
24” [610 mm], 30” [760 mm], 36” [915 mm], 69” [1755 mm]
,
90” [2285 mm]
Backup type:
Tension strut, Concrete
Transition Panel(s) on which side?
Left, Right, Both, None
Transitioning to:
W-beam guardrail, Thrie beam guardrail, Safety shape barrier, Quad-Beam™
end shoe, Vertical face wall