background image

1

Note: 

This kit must be installed or serviced by a qualified installer, service agency or gas supplier. 

These instructions are to be used in conjunction with the main installation instructions for the above 

listed models.

WARNING: If these instructions are not followed exactly, a fire or explosion may result 

causing property damage, personal injury or loss of life.
GROUNDING:

 This power supply must be installed and grounded in accordance with local codes, 

or in the absence of local codes, with the current 

Canadian Electrical Code

 CSA C22.1. or in the 

USA the 

National Electrical Code 

ANSI/NFPA70 latest edition.

Description of System

The models listed above have been designed to 

accommodate the installation of a 150CFM air 

circulation fan. 
Operated via the remote control handset and having 

variable speed control, the fan is designed to boost the 

natural convection through the heater; this may be a 

desirable feature dependent on the fireplace location 

and room layout. 

It is preferable to install the circulating fan before 

the heater is installed

 although it may also be 

retrofitted at a later date provided power is available 

at the fan location. However, please note that the 

retrofitting of the fan is done by disconnecting the 

gas and removing the heater form the cavity. Once 

installed, the fan may be serviced from inside the 

firebox without removing the heater from the cavity 

(780 only).
The fan is designed for automatic operation to come 

on and off when the burner comes on and off. The 

fan speed can be controlled from the remote control 

handset. There are four speeds available. The fan 

will start approximately 4 minutes after lighting the 

appliance and will continue to run for approximately 10 

minutes after the burner is shut off. The fan will go on 

and off at the speed last selected by the user.

795CFK CIRCULATING FAN KIT

INSTALLATION and OPERATING INSTRUCTIONS

CSA approved for use only with

Valor models 780 and 785

4002487-02

© 2010, Miles Industries Ltd. All rights reserved.

G4 S

erieS

Operation

To operate the fan, press the “SET” button on the 

remote handset until only the fan icon (       ) appears 

on the display and is flashing. Press the up/down 

buttons to set the fan speed (     ). No bars showing 

means the fan is OFF. Once the flashing stops, the fan 

is set. The fan icon and number of bars will show when 

the remote is in other modes to confirm the fan status.
Note: The fan, when plugged in, provides power for 

the remote control receiver via the fan control module. 

Therefore batteries are no longer required in the 

receiver other than for back-up purposes. A battery is 

still required in the remote control handset.

Electrical Requirements

The fan kit requires a power supply of 

120 Volts, 

1 phase, 60 Hz. Full load current is less than 1 amp

.

Summary of Contents for 795CFK

Page 1: ... cavity Once installed the fan may be serviced from inside the firebox without removing the heater from the cavity 780 only The fan is designed for automatic operation to come on and off when the burner comes on and off The fan speed can be controlled from the remote control handset There are four speeds available The fan will start approximately 4 minutes after lighting the appliance and will con...

Page 2: ...fan mounting hole and apply the self adhesive wiring diagram label provided to the rear side of the fan access panel as shown 6 foot electrical cord Fan control wire module to receiver Wiring diagram Fan control module Fan enclosure Note the fan access panel is accessible from the inside of the firebox for servicing 780 only see servicing section c Remove the left side valve access panel 5 screws ...

Page 3: ...operated with the remote control system It has 4 speed levels On the remote control handset s display this icon represent the fan and this icon represents the speed One bar is low four bars is high 1 Add a 1 9 V battery to the remote control handset 2 On the remote handset briefly press the SET button to fan mode The fan icon flashes 3 Press the large flame button to activate the fan function and ...

Page 4: ... b Below the gas valve turn the switch off O so the fireplace does not start accidentally c Remove the window the ceramic rocks or logs and the grate logs only d Remove the rear log support 3 screws Remove for maintenance 780 Window logs rocks ceramic walls Rear log support Front brick support Air baffle Fan access panel WARNING DO NOT TOUCH THE FIREPLACE WHILE IT IS HOT Let it cool first before a...

Page 5: ... to remove the fan control module remove the fan first The module is on the left hand side of the fan and it is held in place by a piece of Velcro a Pull the fan out of the enclosure as indicated in step 2 DO NOT FORGET TO CUT THE POWER TO THE FAN FIRST b Pull the fan control module out carefully as it is still connected to the power cord and to the receiver c Disconnect the power the fan and the ...

Page 6: ... the fireplace 2 screws and slide it out of the firebox d Pull the appliance out of the cavity You need access to the left hand side and the rear of the appliance 2 Remove the left side valve access panel 5 screws 3 Disconnect the fan from electric power WARNING DO NOT TOUCH THE FIREPLACE WHILE IT IS HOT Let it cool first before any maintenance WARNING TO AVOID ELECTRIC SHOCK disconnect the power ...

Page 7: ...t within the enclosure to avoid any vibration when functioning 2 Removing the fan control module The module is held in place by a piece of Velcro Disconnect the power the fan and the receiver connectors to release the module Note Grab the whole connector when disconnecting DO NOT pull on the wires 3 Reconnect and reinstall the module and the fan after servicing if disconnected 4 Refit the fan encl...

Page 8: ...ove the grounded prong from this plug Designed and Manufactured by for Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver B C CANADA V7H 3B1 Tel 604 984 3496 Fax 604 984 0246 www valorfireplaces com Because our policy is one of constant development and improvement details may vary slightly from those given in this publication NOTE ALL WIRING IS SPECIFIC TO THIS KIT AND SHOULD ONLY BE ...

Page 9: ...sélectionnez la vitesse d abord Sur la manette de la télécommande appuyez sur le bouton SET plusieurs fois jusqu à ce que l icône du ventilateur apparaisse et clignote Appuyez sur les deux boutons des flammes pour régler la vitesse indiquée par l icône Aucune barre noire sur l icône de la vitesse indique que le ventilateur est arrêté et ne fonctionnera pas automatiquement Le ventilateur est réglé ...

Page 10: ...lé le ventilateur collez l étiquette du schéma des connexions sur le panneau d accès au ventilateur tel qu indiqué Note le panneau d accès au ventilateur est accessible de l intérieur de la boîte de foyer pour l entretien voir la section sur l entretien c Enlevez le panneau d accès à la soupape sur le côté gauche de l appareil 5 vis d Déballez le contenu du kit De l arrière de l appareil faites pa...

Page 11: ...notera 3 Appuyez sur le bouton de la grande flamme pour activer le ventilateur et augmenter sa vitesse 4 Appuyez sur le bouton de la petite flamme pour réduire la vitesse du ventilateur ou pour l éteindre NOTE Huit 8 secondes après la programmation du ventilateur la manette se mettra automatiquement en mode température TEMP Le ventilateur se mettra en marche automatiquement à la vitesse maximale q...

Page 12: ... allume pas accidentellement c Enlevez la fenêtre les bûches ou pierres de céramique et le porte bûches version bûches seulement Enlevez pour l entretien 780 Fenêtre bûches pierres panneaux Support de bûche arrière Support de briques avant Déflecteur d air Panneau d accès au ventilateur AVERTISSEMENT NE TOUCHEZ PAS LE FOYER LORSQU IL EST CHAUD Laissez le refroidir avant tout entretien d Enlevez le...

Page 13: ...du ventilateur enlevez d abord le ventilateur Le module est situé à gauche du ventilateur et il est maintenu en place par une pièce de Velcro a Sortez le ventilateur hors de son boîtier tel qu indiqué à l étape 2 ATTENTION N OUBLIEZ PAS DE DÉBRANCHER LE COURANT ÉLECTRIQUE D ABORD b Tirez gentiment le module du ventilateur hors du boîtier car il est toujours branché au cordon d alimentation et au r...

Page 14: ... d Tirez l appareil hors de sa cavité Vous devez avoir accès au côté gauche de l appareil et à l arrière 2 Enlevez le panneau d accès à la soupape sur le côté gauche 5 vis 3 Débranchez le ventilateur du courant électrique Débranchez le fil de commande du ventilateur au récepteur Fil de commande du ventilateur 4 Débranchez soigneusement le fil de commande du ventilateur au récepteur 5 À l arrière d...

Page 15: ...pièce de Velcro Débranchez les bornes du cordon d alimentation POWER du ventilateur FAN et le fil du module au récepteur Notez Débranchez les bornes à pince NE TIREZ PAS SUR LES FILS 3 Rebranchez et réinstallez le module de commande s il a été débranché ou déplacé pour l entretien 4 Réinstallez le boîtier du ventilateur en le fixant au panneau arrière de l appareil 9 vis 5 Faites passer le fil du ...

Page 16: ...CTURER VIS DE MISE À LA TERRE CORDON ÉLECTRIQUE DE 6 PIEDS 1 9 M MIS À LA TERRE BOÎTIER DU VENTILATEUR VENTILATEUR MODULE DE COMMANDE VENTILATEUR RÉCEPTEUR DE TÉLÉCOMMANDE FOURNI AVEC LE FOYER NOTE LE FILAGE ET LES BORNES SONT SPÉCIFIQUES À CE KIT ET NE DEVRAIENT ÊTRE REMPLACÉS QUE PAR DE L ÉQUIPEMENT ORIGINAL DU MANUFACTURIER BORNES MOLEX VENTILATEUR MODÈLE 795CFK VENTILATEUR DE CIRCULATION D AIR...

Reviews: