BUS BODY ELECTRONICS
9
➔
Reset the counter with
(after resetting, the coun-
ter shower the value 1 if the error persists).
2.7.1.3 Ending
Press
and
buttons for 2 seconds
➔
Normal operating display appears (Figure 15).
2.7.2 Error overview
Error code
Component
Cause
Remedy
F001-015
Not used
F016
EDS
➢
Restart system
F017
Pressure sensor
➢
Defective sensor
➢
Wiring harness de-
fective
➢
Inspect wiring harness
➢
Replace sensor
F018
Duct/convector temper-
ature sensor
➢
Defective sensor
Wiring harness defec-
tive
F019
Ice sensor
➢
Defective sensor
Wiring harness defec-
tive
F020
Room temperature sen-
sor
➢
Defective sensor
Wiring harness defec-
tive
F021
Environmental tempera-
ture sensor
➢
Defective sensor
Wiring harness defec-
tive
F022
Ice sensor
➢
Icing
➢
Temperature too low
Wait until sensor has de-
frosted
F023
F024
High pressure
Low pressure
Brief system over-
load
because
of
high motor speed at
high environmental
temperature
The system turns off for
5 minutes and tries to
restart. If the error code
persists, consult our
service center
F025-32
Not used
Table 1 - SC600 error code overview
Figure 15 - SC600 normal operating
display