BUS BODY ELECTRONICS

 

 

 

  Reset the counter with 

 (after resetting, the coun-

ter shower the value 1 if the error persists). 

2.7.1.3 Ending 

Press 

 and 

 buttons for 2 seconds 

  Normal operating display appears (Figure 15). 

 

2.7.2  Error overview 

Error code 

Component 

Cause 

Remedy 

F001-015 

Not used 

 

 

F016 

EDS 

 

 Restart system 

F017 

Pressure sensor 

 Defective sensor 

 Wiring harness de-

fective 

 Inspect wiring harness 

 Replace sensor 

F018 

Duct/convector  temper-
ature sensor 

 Defective sensor 

Wiring  harness  defec-
tive 

F019 

Ice sensor 

 Defective sensor 

Wiring  harness  defec-
tive 

F020 

Room  temperature  sen-
sor 

 Defective sensor 

Wiring  harness  defec-
tive 

F021 

Environmental  tempera-
ture sensor 

 Defective sensor 

Wiring  harness  defec-
tive 

F022 

Ice sensor 

 Icing 

 Temperature too low 

Wait until sensor has de-
frosted 

F023

 

F024 

High pressure 
Low pressure 

Brief  system  over-
load 

because 

of 

high motor speed at 
high  environmental 
temperature 

The system turns off for 
5  minutes  and  tries  to 
restart. If the error code 
persists,  consult  our 
service center 

F025-32 

Not used 

 

 

Table 1 - SC600 error code overview 

Figure 15 - SC600 normal operating 
display 

Summary of Contents for SC600 Revo-E Byd Hybrid

Page 1: ...Rev 21 11 2018 Id No DOK30609 BUS BODY ELECTRONICS SC600 REVO E BYD HYBRID Operating instructions Busdriver...

Page 2: ...4 Description of the display 4 1 5 Mode overview 5 2 Use 6 2 1 Activation deactivation 6 2 1 1 Activation 6 2 1 2 Deactivation 6 2 2 Auto mode 6 2 2 1 Activation 6 2 2 2 Deactivation 7 2 3 Configuring...

Page 3: ...re 7 SC600 Auto mode activated Cooling mode 6 Figure 8 SC600 Auto mode activated Heating mode 6 Figure 9 SC600 Auto mode deactivated 7 Figure 10 SC600 recirculating air function activated 7 Figure 11...

Page 4: ...erface between human and machine that is integrated into the dashboard This control panel allows the driver to control the roof top air conditioning system that has ven tilation cooling and heating fu...

Page 5: ...f the display 1 Display 2 On off button 3 UP 4 DOWN 5 Function status light 6 Blower button 7 Fresh air recirculating air button 8 Auto button A Desired value display room temperature B Blower level m...

Page 6: ...unctions and infor mation summarized under point 2 as well as Error mode The normal operat ing display includes all of the elements provided here in the example Error detection mode Mode to display al...

Page 7: ...f Mode is on corresponding status light and function symbol light up on the display Figure 6 Note Auto mode can be turned on only if the motor has been started Note If Auto mode is on the system autom...

Page 8: ...The system then controls the fresh air valves automatically Pressing the button again within 10 minutes will de activate the manual recirculating air function The system then controls the fresh air va...

Page 9: ...s and buttons at the same time for 2 seconds Mode is on Error code F001 and occurrence count 1 here will be displayed Figure 14 2 7 1 2 Reading out errors Scroll through the error codes with or Note D...

Page 10: ...tive sensor Wiring harness defec tive F019 Ice sensor Defective sensor Wiring harness defec tive F020 Room temperature sen sor Defective sensor Wiring harness defec tive F021 Environmental tempera tur...

Page 11: ...Valeo Thermal Commercial Vehicles Germany GmbH Postfach 1371 82198 Gilching Germany Tel 49 0 8105 7721 0 Fax 49 0 8105 7721 889 www valeo thermalbus com service valeobus valeo com...

Reviews: