BURNER COVER:
CRUSHED GLASS
MEDIA ALLOWED.
A
DETAIL A
ACCENT LIGHT COVER:
CRUSHED GLASS
MEDIA PROHIBITED.
ACCENT LIGHT GLASS PANELS:
CRUSHED GLASS
MEDIA ALLOWED.
CAUTION:
DO NOT PLACE CRUSHED
GLASS MEDIA IN THE RECESSED
AREA AROUND THE PILOT, PILOT
SENSOR OR IGNITOR PROBE.
7.3 Final Steps
Re-install the glass door assembly. Test fire to ensure there is minimal contact between the flame and
the logs and rocks.
1. If the test fire is acceptable, re-install the barrier screen assembly.
2. If during the test firing there seems to be significant flame impingement on the cross logs, there are
two steps that can be taken to reduce the impingement:
(a) Pivot log left or right to move away from flame.
(b) Thin out crushed glass directly under the cross log. This can reduce the height of the flame
directly under the log.
CAUTION
Do not operate the fireplace with glass panel removed, cracked or broken.
Replacement of the panel should be done by a licensed qualified service person.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause
property damage, personal injury or loss of life. Installation and service must be