VIP-9895 

IP EMERGENCY WALL MOUNT CALL STATION 

 
 

INTRODUCTION

 

The VIP-9895 IP Emergency Wall Mount Call 
Station provides emergency communication to 
any SIP telephone, SIP address, PC softphone, 
Valcom intercom station or to a Valcom IP 
Gateway.  At the time of activation, the high 
intensity blue LED changes from beacon mode 
to flash mode.  The LED will continue to flash 
until the call is terminated.  When the called 
party answers, handsfree talkback 
communication is enabled.  When the called 
party terminates the call, the connection is 
terminated automatically. 

 

SPECIFICATIONS 

 

Features 

 

Power over Ethernet (PoE) (802.3af) 

 

Compatible with most modern IP telephone 
systems 

 

Call button calls a SIP address or any 
Valcom Gateway 

 

Automatic Talkback VOX operation (no push 
to talk button needed) 

 

SIP or Multicast addressable 

 

All Call thousands of units with Valcom 
Gateway 

 

Red LED status indicator 

 

Combination LED Beacon/Flasher 

 

Compatible with secure networks 

 

Supervision with alert functions 

 

Network programmable for control and setup 

 

High survivability 

– No server needed 

 

Vandal and Tamper resistant 

 

Stainless steel enclosure, brushed stainless 
steel grille and hardware 

 

Available in several standard color 
combinations 

 

Environment

 

 

Suitable for Indoor/Outdoor installations

Mounting

 

 

Surface mount 

 

Power

 

 

PoE: 802.3af, class 3 

 

Speaker Output

 

 

100dB@4’ on-axis

 

 

High efficiency design for voice

 

       intelligibility

 

 

Networking

 

 

10/100 Mbps Ethernet port 

 

Manual or Dynamic Host Configuration 
Protocol (DHCP) IP address setup 

 

Dimensions/Weights

 

 

32.15” H x 9.9” W x 8.0” D 

       (81.66 cm x 25.1 cm x 20.3 cm) 

 

Shipping weight: 39.75 lbs. (18.1kg) 

 

INSTALLATION

 

When removing or reinstalling security 
screws, start screws by hand before 
tightening with a hand or power driver tool.  
If using a power driver, operate it at very low 
speed to help prevent thread seizing. 

 

 

Using security hex driver carefully remove 
top and set aside with hardware. 

 

Using the security hex driver, carefully 
remove the front speaker panel.  While 
supporting the panel, unplug connector from 
main circuit board at the top of the speaker 
(“A” in photo).  Loosen screws from relay 
connector on the small circuit board 
attached to the speaker housing, and 
disconnect the two white wires from the 
relay (“B” in photo).  Set speaker panel and 
hardware aside. 

 

Install base using appropriate hardware, 
with 

supplied (4) 1.5” neoprene washers 

between base and mounting surface. 

 

Connect earth ground to base (ground may 
be connected using one of the mounting 
screws). 