background image

Issue 1

1

947023

V-9924C

COMMON AUDIBLE RINGING UNIT

GENERAL

The Common Audible Ringing Unit provides an
audible signal over the paging system when
there is an incoming call.  It is used between a
telephone system and the public address
system.

SPECIFICATIONS

Activation

  1A2 Bell/Buzzer ICM

  PABX Station Port

 Contact 

Closure

Features

  Activates via ringing voltage, buzzer voltage

or contact closure

  Capable of switching signal to three zones

simultaneously

  Uses standard 1A2 key system voltages

  Each zone is equipped with a 5 Watt

amplifier and volume control

  Screw terminal connection

  Compact size, can be mounted on wall or in

cabinet

  Automatically switches paging speakers

from paging system to audible signal of the
V-9924C during the ring interval of the
incoming call

  Variable pitch control

  Two auxiliary contact closures

Other Materials Required

 

-

24VDC power supply

  Cat 3 or 5 twisted pair telephone cable

  Mounting screws and hardware

Dimensions/Weight

  8.20" H x 4.55" W x 2.30" D

(20.83cm H x 11.56cm W x 5.84cm D)

  1.3 lbs. (0.59kg)

Power Requirements

The V-9924C  requires a -24VDC "B" battery
and draws 50mA idle and 300mA maximum
operating.

Signal Requirements

The V-9924C requires interrupted ringing or
buzzer voltage or dry contact closure to operate.
The output of the V-9924C will follow the
interruptions of the input.  The ringing voltage
should be approximately 90VAC and the current
requirement would be 8mA.  The buzzer voltage
should be approximately 18VAC and the current
requirement would be 10mA.  The V-9924C
pulls approximately 3mA through a dry contact
closure for activation.  Ringing and buzzer
voltages cannot be applied simultaneously.  Use
only one method of activation.