background image

                                                                         Issue 3

1

947187

by

PagePac

®

PAGEPAC PLUS ZONE EXPANSION UNIT

V-5335100

INTRODUCTION

The Zone Expansion Unit (ZEU) provides up to
16 zones of audio output (including talkback),
contact closure outputs or inputs.

SPECIFICATIONS 

(see Table 2)

FEATURES

  Provides same features as PagePac Plus

Controller

  Maximum of 3 ZEUs per Controller

Power Requirements

  Power from the PagePac Plus Controller

   through the interconnect cable

Dimensions/Weight

  16.00”W x 1.75”H x 6.88”D

   (40.64cm x 4.45cm x 17.48cm)

  3.0 lbs (1.36 kg)

Environment

  Temperature         0 to +40° C (+32 to +104° F)

  Humidity: 

         5 to 95% (non-condensing)

Locate in an area free of excess moisture,
corrosive gases, dust and chemicals.

INSTALLATION

MOUNTING

NOTE:

 

 When installing the Zone Expansion

Unit, leave at least four inches of space above
and below for proper ventilation.

Installing the paging equipment in a ventilated
room where there is easy access to speaker
cabling (preferably in the telephone equipment
room).  Disconnect all power before installing
equipment.

1. Mount the Zone Expansion Unit(s) (ZEU) to

either a wall, cabinet or a rack (below the
controller).

2.  Connect 8-pin Molex from Controller to first

ZEU, and next ZEUs, if used.

NOTE:  Up to 3 ZEUs can be used, providing
up to 56 paging and/or control zones.

3. Set DIP switches on each ZEU(s).
4. Set the Zone Option switches on the

Controller and ZEU(s).

NOTE:  For each zone used, no matter what
its function, this switch needs to be set to one
of three settings for proper zone operation
before applying power to the system.

The Controller has eight switches for zones 1-8.
Each subsequent ZEU has switches for zones
9-24, 25-40 and 41-56.

Refer to the Zone Map and Zone Configuration
Tables filled out during facility paging system
design.  You can find these in the PagePac®
System Installation and Configuration Guide.

5. Locate and mount all speakers in accordance

with the floor plan drawing for this
installation.

6. Connect each speaker to the appropriate

Home Run or Speaker-to-Speaker wiring
scheme as shown on the floor plan.

NOTE:  Adjust all speakers per volume and
power requirements as noted on floor plan,
during or after installation.

Summary of Contents for V-5335100

Page 1: ...all power before installing equipment 1 Mount the Zone Expansion Unit s ZEU to either a wall cabinet or a rack below the controller 2 Connect 8 pin Molex from Controller to first ZEU and next ZEUs if used NOTE Up to 3 ZEUs can be used providing up to 56 paging and or control zones 3 Set DIP switches on each ZEU s 4 Set the Zone Option switches on the Controller and ZEU s NOTE For each zone used no...

Page 2: ...stem does not respond as described refer to the Troubleshooting section of this guide and or the PagePac Plus System Installation and Configuration guide for detailed troubleshooting 2 Begin programming the Controller A quick reference card for telephone programming along with detailed programming instructions can be found in the PagePac Plus System Installation and Configuration Guide Programming...

Page 3: ...ensions and Weights Height 1 75 4 45cm Width 16 00 40 64cm 19 00 48 26cm with brackets attached Depth 6 88 17 48cm Weight 3 0 lbs 1 36kg Electrical Relay Contacts Control Contact Closure Contacts are rated at 120VAC 50VDC at 1 Amp Audio Zone Contacts are rated at 2 Amps Temperature Range 0 to 40 C 32 to 104 F operational 40 to 66 C 40 to 150 F storage and shipment Humidity Range 5 to 95 non conden...

Page 4: ...NT 12 24 TYPICAL 19 10 TEL LINE INPUT CHANNELS POWER POWER PagePac Plus AmpliCenter D300 PagePac Plus Controller Call Stacker PagePac Plus AmpliCenter D300 PagePac Plus Controller Call Stacker Figure 2 Rack Mounted Hardware Figure 3 8 pin Molex Connector from Controller to Zone Expansion Unit s ...

Page 5: ...5 Figure 4 Setting Zone Expansion Unit Dip Switches Figure 5 Setting Zone Option Switches on Controller and Zone Expansion Units ...

Page 6: ...6 Figure 6 Speaker Wiring Methods Figure 7 Zone Wiring Using Connector Blocks ...

Page 7: ...7 INPUT CONTACT CLOSURE Figure 8 Speaker and Contact Closure Zone Wiring to Controller Figure 9 Zone Expansion Unit Back Panel ...

Page 8: ... to Valcom are prepaid 5 all units out of warranty are subject to a service charge The service charge will cover minor repairs major repairs will be subject to additional charges for parts and labor This warranty is in lieu of and excludes all other warranties expressed or implied and in no event shall Valcom Inc be liable for any anticipated profits consequential damages loss of time or other los...

Reviews: