background image

 

 

VSP-V-2970 

 

 

Issue 3 

 

947014

 

 

 
 
 

V-2970 

EMERGENCY/NORMAL CALL SWITCH  

WITH VOLUME CONTROL

 

 

 
INTRODUCTION 

The V-2970 is an Emergency/Normal Call Switch 
with Volume Control designed to be used with the  
V-2924A and V-2925A Page Control Units.  The    
V-2970 is provided with an "Emergency" call button 
and a "Normal" call button for connection to 
customer provided signaling equipment. 
 
The "Emergency" button transposes a single press of 
the button into the four required closures required to 
generate an "Emergency" class of service call.   The 
"Normal" call button allows a "Normal" class of 
service call.  
 

DIMENSIONS/WEIGHT 

• 

4.50"H x 2.75"W x 1.00"D 
(11.43cm H x 6.99cm W x 2.54cm D) 

• 

0.2 lbs. (.09 kg) 

 

FEATURES 

• 

Designed to fit a single-gang electrical box 

• 

No external power source required 

• 

Red "Emergency" button for emergency call 

• 

Black "Call" button for normal call 

• 

Built-in Volume Control 

 

CONNECTIONS/SETUP 

1.  Connect switch inputs from control unit to  

V-2970 as shown in connection diagram. 

2.  Connect Tip and Ring from control unit to  

V-2970 as shown in connection diagram. 

3.  Connect V-2970 to Tip and Ring of 45 Ohm 

Talkback Speaker. 

4.  Press either call button to test loudness of tone at 

speaker and adjust volume of tone through  
cut-out on the front of the V-2970 enclosure 
using a 1/16 inch flat tip screwdriver. 

5.  Place V-2970 over standard single -gang 

electrical box and fasten in place using the two 
screws provided. 

 

 

 
TECHNICAL ASSISTANCE 

When trouble is reported, verify that power is being 
supplied to the unit and there are no shorts or grounds 
on cabling. 
 
Assistance in troubleshooting is available from the 
factory.  When calling, you should have a VOM and 
a telephone test set available and be calling from the 
job site.  Call (540) 563-2000 for Technical Support 
or (540) 767-1555 for Valcom 24-hour Faxb ack 
System or visit our website at 
http://www.valcom.com. 
 
Valcom equipment is not field repairable.  Valcom, 
Inc. maintains service facilities in Roanoke, VA.  
Should repairs be necessary, attach a tag to the unit 
clearly stating company name, address, phone 
number, contact person and the nature of the 
problem.  Send the unit to: 

 

Valcom, Inc. 

Repair and Return Dept. 

5614 Hollins Road 

Roanoke, VA  24019-5056 

 

 

 

 

 

 
 
 
 

Reviews: