background image

2

947305

P A B X ,

E L E C T R O N I C

O R   1 A 2   K E Y  

S Y S T E M   O R

D E D I C A T E D

S I N G L E   L I N E

T E L E P H O N E

V - 2 9 9 0

  R I N G

D O W N

D E V I C E

      V - 2 9 2 0

C O N T R O L

          U N I T

    4 5   O H M

T A L K B A C K

S P E A K E R

C A L L   B U T T O N

( U P   T O   2 0   Z O N E S )

F I G U R E   1

S I M P L I F I E D   B L O C K   D I A G R A M   O F   A   T Y P I C A L   I N S T A L L A T I O N

Dimensions/Weight

 

Control Unit - 8.55" H x 11.0" W x 2.35" D
(21.72cm H x 27.94cm W x 5.97cm D)

 

6.7 lbs. (3.04 kg)

 

Ring Down Device – 8.2”H x 4.55”W x 2.3”D
(20.83cm H x 11.56cm W x 5.84cm D)

 

1.25 lbs. (.57 kg)

 

Power Supply – 3.0”H x 2.5”W x 2.0”D
(7.62cm H x 6.35cm W x 5.08cm D)

 

0.8 lbs. (.36 kg)

Nominal Specifications

V-2920 - Control Unit

 

Input Impedance:

600 Ohms

 

Input Level:

 -10 dBm

 

Output Impedance:

45 Ohms

 

Aux/Music Input:

8-600 Ohm low level

V-2990 - Ring Down Device

 

Input Impedance:

600 Ohms

 

Output Voltage:

90 Vac ring generator

VP-324 - Power Supply

 

- Output:

24 Vdc +/- 3 V "B" Battery

(Unfiltered Signal Battery)

Numbering Plan

 

The dialing codes are 10 to 29 and 0 for all call.

Auxiliary Contacts

The V-2920 is equipped with 6 sets of auxiliary
contact closures.  They are:

Lamp Contact

Operates on loop closure.

Ring Contact 

Follows ringing cycle 2
seconds "ON", 4 seconds
"OFF".

Zone 26 Contact  Operates when station 26 is dialed

and the "*" key is pressed.

Zone 27 Contact  Operates when station 27 is dialed

and the "*" key is pressed.

Zone 28 Contact  Operates when station 28 is dialed

and the "*" key is pressed.

Zone 29 Contact  Operates when station 29 is dialed

and the "*" key is pressed.

Volume Controls

The V-2920 is equipped with 5 volume controls.

 

Phone to Speaker  -  Adjusts the transmit volume.

 

Speaker to Phone  -  Adjusts the receive volume.

 

Music 1 adjusts background music for zones
10-19.

 

Music 2 adjusts background music for zones 
20-29.

 

All Call adjusts the one-way all call level.

Power Requirements

V-2920 - Control Unit
Voltage: 115 

Vac

Power:   

30 Watts

V-2990 - Ring Down Device
Power:

-21.5 to -26.0 Vdc, 200 mA

VP-324 - Power Supply
Input:

105-120 Vac, 60 Hz, 18 watts

Environment

 

Temperature:

0 to 40 Degrees C

 

Humidity:

0 to 85% non-precipitating

Summary of Contents for V-2920

Page 1: ...on equipped with a call button to call the attendant location Components The V 2920 system consists of three components A V 2920 Control a V 2990 Ring Down Device and a VP 324 Power Supply Access PABX...

Page 2: ...ery Unfiltered Signal Battery Numbering Plan The dialing codes are 10 to 29 and 0 for all call Auxiliary Contacts The V 2920 is equipped with 6 sets of auxiliary contact closures They are Lamp Contact...

Page 3: ...the key on the telephone key pad after the zone has been called These contacts can be used to operate electric strike plates on doors The V 2920 provides a background music input and is designed to au...

Page 4: ...re 4 Music Connections The output of a low level music source connects to W OR OR W on block J1 of the control unit NOTE Do not connect the output of a high power amplifier to this input AC Power Conn...

Page 5: ...et Zone 22 Spk 36 11 37 12 38 BK BL BL BK BK O O BK BK G Sta 17 Gnd Sta 18 SW Sta 18 Gnd Sta 19 SW Sta 19 Gnd 13 39 14 40 15 G BK BK BR BR BK BK S S BK Zone 22 Ret Zone 23 Spk Zone 23 Ret Zone 24 Spk...

Page 6: ...ty mode the zones can be used for door locations or other areas not requiring immediate response from the attendant These zones will be bumped from their place in queue and put at the end of the line...

Page 7: ...e 29 Contact Operates when zone 29 is dialed and the key is pressed TABLE 2 DIPSWITCH FUNCTIONS SWITCH OFF POSITION ON POSITION 1 2 3 4 5 6 7 8 Normal queue sequence on zone 26 Normal queue sequence o...

Page 8: ...8 947305...

Page 9: ...E 5 CONTROL AND CONNECTOR LOCATIONS BL W W BL W BR BL R T R Inhibit Ground J1 Connecting Block V 2990 Tel Sys C O Line position or loop start trunk port T R A A1 5 1k ohm FIGURE 6 INHIBIT OPTION Dedic...

Page 10: ...defective device within the warranty period provided that 1 inspection by Valcom Inc indicates the validity of the claim 2 the defect is not the result of damage misuse or negligence after the origina...

Reviews: