background image

 

 

 

 

 
  
 

Issue 5, June 1995

  (540) 427-3900 

 
 

 

V-2001 

 

INTEGRATED SINGLE ZONE (PLUS) 

 

PAGE CONTROL UNIT

 

 
 
INTRODUCTION

 

The V-2001 is an Integrated Single Zone Paging 
Control Unit for use with any electronic key or PABX. 
 The Control Unit provides external power of 1 amp of 
-24vdc (20 Valcom  power units) for powering Valcom 
One-Way Amplified Speakers. 
 
These instructions contain the specifications and 
information necessary to install, operate, and maintain 
the Integrated Single Zone (Plus) Paging Control Unit. 
  
The V-2001 Page Control Unit is manufactured by 
Valcom, Inc., 1111 Industry Avenue, Roanoke, VA  
24013. 
 

"WARNING:  To reduce the risk of fire or 
electric shock, do not expose this appliance to 
rain or moisture." 
 
"WARNING:  Shock Hazard - Do Not Open." 
 
"AVIS:  Risque de Choc Electrique ne pas 
Ouvrir." 
 
"PELIGRO:  Corriente Electrica - No Abra." 

 
 

SPECIFICATIONS

 

Purpose

 

- Provides telephone system access to a single zone 
  of one-way paging. 
 

Applications

 

- Electronic Key Systems  
- PABX's  
- 1A2 Key Systems (400 type line card required) 
- Stand Alone Systems  
 
Refer to Figure 1 for a block diagram of a typical 
installation. 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Features

 

- Electronic key system line key access 
- PABX loop start trunk port access 
- Page port access 
- Page override capability (using C. O. line 
  position or loop start trunk port) 
- Switchable battery feed for loop start operation 
- RJ11 for Tip and Ring connections 
- Power on LED 
- AGC on all voice outputs 
- Directly drives up to 150 Valcom one-way 
  amplified speaker assemblies per output 
- Background music input 
- Voice operated switch to mute music during page 
- Removable screw terminals provided 

 

 

  

Summary of Contents for V-2001

Page 1: ...r moisture WARNING Shock Hazard Do Not Open AVIS Risque de Choc Electrique ne pas Ouvrir PELIGRO Corriente Electrica No Abra SPECIFICATIONS Purpose Provides telephone system access to a single zone of...

Page 2: ...r powering Valcom One Way Amplified speakers Page music outputs 2 provided music mutes during page Page w o music output Battery Backup input use Valcom VPB 260 battery backup supply AC powered AC inp...

Page 3: ...ery backup supply Valcom VPB 260 or equivalent in case of AC power failure Environment Temperature 0 to 40 Degrees C Humidity 0 85 non precipitating SYSTEM DESIGN General The Valcom V 2001 Integrated...

Page 4: ...y disconnect when you hang up re establishing the overridden page announcement INSTALLATION Precautionary Designations Mounting The V 2001 was designed for wall or table mounting When wall mounting th...

Page 5: ...sic and one without music __ 5 Connect Ring of the one way amplified speakers to the remaining screw terminal of the desired page out on the V 2001 __ 6 Connect the 24vdc terminal or lead of the one w...

Page 6: ...6...

Page 7: ...7...

Page 8: ...8...

Page 9: ...the V 2001 It requires the use of a vacant C O line position or vacant loop start trunk port in addition to the page port vacant C O Line position or vacant loop start trunk port used for primary acce...

Page 10: ...t field repairable Valcom equipment contains no user serviceable parts inside Valcom Inc maintains service facilities in Roanoke VA Should repairs be necessary attach a tag to the unit clearly stating...

Page 11: ...cts to Valcom are prepaid 5 all units out of warranty are subject to a service charge The service charge will cover minor repairs Major repairs will be subject to additional charges for parts and labo...

Reviews: