INTRODUCTION
The VIP-204B SIP Paging Gateway is designed
for use with virtually all IP based telephone
systems. The unit provides SIP addressable
groups and 4 analog outputs that may be
included as part of the SIP addressable groups.
The VIP-204B can control thousands of IP
speakers and/or analog speakers or provide an
interface to legacy paging systems.
Connection to a SIP server can be as individual
SIP Stations (extensions) or as a SIP trunk.
Station mode provides up to 8 SIP-addressable
groups. Trunk mode accepts up to 100 SIP
phone numbers for flexible grouping.
SPECIFICATIONS
Access Methods
SIP
Valcom Multicast Page Group
Features
SIP
– Addressable Groups (phone numbers)
4 Analog Audio Outputs
4 Programmable Form A Relay Closures
RJ-45 for Network Connection
Provides Audio for Valcom Analog One-Way
Self Amplified Speaker Assemblies or 25/70
Volt central amplifiers
AUX Audio Input via RCA Jack for
Background Music Input, Music Mutes During
a Page
Output Control Relay Closure Provided
During Paging Output
2.5mm Jack for optional DC Power (non-
PoE)
LED Status Indicator
Network Activity LEDs
Programmable Feedback Elimination/Page
Repeat
Programmable Night Ring
Power Options
Power over Ethernet (PoE) 802.3af, Class 3
Compatible
Optional External Power Supply (VIP-324D)
Dimensions/Weight
1
Standard 19” Rack Unit:
1
.75” H x 16.5" W x 11.88" D
(4.45 cm x 41.9 cm x 30.18 cm)
Weight: 4.0 lbs. (1.8 kg)
Nominal Specifications
AUX Input Impedance:
8 to 600 Ohms
AUX Input Level:
-10dBm nominal
Output Impedance:
50 Ohms
Output Level:
- 10dBm nominal
Relay Current Rating:
1 Amp @ 24VDC
Nominal Power Requirements
Via rear panel barrel connector:
Voltage:
24VDC
Current:
325mA
Via 802.3af PoE Ethernet Switch:
Class 3
Environment
Temperature:
0 to +40° C
Humidity:
0 to 85% Non-Precipitating
These products are intended for use with a UL
Listed power source marked “Class 2” or “LPS”
rated 24VDC, or 48VDC (PoE).
PoE and all interconnected ITE are intended for
intra-building.
Precautionary Designations
WARNING-To Reduce The Risk Of Fire Or
Electric Shock. Do Not Expose This
Apparatus To Rain Or Moisture.
AVERTISSEMENT - Afin de réduire les
risques d'incendie ou de décharge
électrique, évitez d'exposer le système à la
pluie ou à l'humidité.