background image

PagePac Plus AmpliCenter
V-5328020/V-5328100/V-5328300

Installation and Use

ISSUE 2

947169

by

PagePac

®

Summary of Contents for PagePac Plus AmpliCenter V-5328020

Page 1: ...PagePac Plus AmpliCenter V 5328020 V 5328100 V 5328300 Installation and Use ISSUE 2 947169 by PagePac...

Page 2: ...proper ventilation 1 Mount the PagePac Plus AmpliCenter to either the wall Figure 1 cabinet or a 19 inch rack Figure 2 Figure 1 Wall Mounted Hardware Figure 2 Rack Mounted Hardware SIDE VIEW 210 240...

Page 3: ...h the page output type of your telephone system 6 Insert power cord into AmpliCenter and into wall outlet see Figure 7 7 Test paging zone served by the AmpliCenter by dialing paging telephone extensio...

Page 4: ...O W V O L T A G E O U T P U T T O T I P a n d R I N G T I P A N D R I N G F R O M L O O P S T A R T O R G R O U N D S T A R T P O R T M I C S W I T C H A M P L I C E N T E R B A C K P A N E L H O S T...

Page 5: ...mfortable level 4 Using a telephone from the host system dial the paging extension Speak into the telephone in a normal manner Your voice should be heard from all connected speakers the AmpliCenter Pa...

Page 6: ...Tip and Ring reversed or AmpliCenter not grounded Audio signal not reaching speakers Check wiring at AmpliCenter Verify Page Accessed LED is on Background music cannot be heard Input level not set cor...

Page 7: ...ut ground C1 tip and ring 70V Out Balanced output used for terminating the loudspeaker wiring 6 Screw adjustable potentiometers VOX sensitivity level Music ducking mute level for music during voice pa...

Page 8: ...value of less than 15 ohms must be rechecked for possible shorted wiring or speakers Correct any problems and retest Figure 10 Speaker Run Methods R66B R66B SPEAKERS 66 TYPE CONNECTION BLOCK HOME RUN...

Page 9: ...105 120 VAC 210 2 0 VAC 50 60 Hz 4 Note If the AmpliCenter is used with the PagePac Plus Controller refer to the Controller Installation and Use Guide for detailed instructions MUSIC INPUT 0 dBm OUT T...

Page 10: ...her common grounding methods The Ground Start mode is a two wire interface and has a 600 Ohm input impedance When a trunk is accessed a momentary ground is sent to the ringside of the pair by the host...

Page 11: ...below rated output 20 Hz to 20 kHz bandwidth unweighted Telephone Paging Access Automatic Level Control 15 1 compression ration above 15 dBm input Gain Below Limiting Knee 56 dB ALC Attack Time Less...

Reviews: