1 947730
ISSUE 1
VIP-480L-IC InformaCast® Compliant
IP Paging Horn
INSTALLATION
Mounting (VIP-LLE)
The VIP-LLE Network Extender is designed for wall
or shelf mounting and must be within 300 feet of the
network switch.
Shelf:
Provided with the VIP-LLE Network Extender
are four rubber stick on pads. Peel pads off their
carrier backing and place at the four corners of the
bottom of the unit.
Wall:
Using the brackets and wood screws
provided, secure the VIP-LLE Network Extender
to the wall.
Mounting (horn)
FLUSH MOUNT
The cardboard packing material in which the horn is
shipped also serves as the template for flush
mounting. Using the template, draw the speaker
outline on the wall to be cut. Make appropriate
wiring connections and test the speaker for
operation. Using appropriate mounting screws (not
furnished) drill and mount the flange as shown.
UNIVERSAL BRACKET
Loosen or separate the universal bracket leaves by
loosening or removing the handle and hardware.
Using the back leaf as a template, mark the wall
through the mounting holes. Drill and mount to the
wall using appropriate screws (not furnished) or
mount directly to a junction box.
Mount the T-bracket to the back of the horn as
shown using the (2) ½ inch screws provided.
“C” CLAMP FOR “I” BEAM MOUNTING
A “C” clamp is provided with the horn to allow
mounting to a beam. Attach the “C” clamp to the
back of the horn as shown using the (2) ½ inch
screws provided. Place the bolt through the hole in
the bottom of the base to secure the “C” clamp to
the beam. It is suggested that the horn be mounted
to the underside of the “I” beam to provide
maximum positioning adjustments.
Interconnections
The only method of powering a VIP-480L-IC IP
Paging Horn is via a Power over Ethernet (PoE)
switch or power injector meeting the 802.3af
specification.
Make all required signal connections before
connecting to Ethernet switch or power injector
meeting the 802.3af specification. Power is
supplied to the horn assembly via the VIP-LLE
Network Extender.
Network Connection
As shown in Figure 1, the LLE Network Extender
has one RJ-45 network connector on the front
panel. Use a standard Ethernet patch cable to
connect the NETWORK connector of the LLE
Network Extender to a 802.3af compliant PoE port
(300 feet maximum distance).
Signal Connections
As shown in Figure 1 and 2, audio output
connections are made on the rear panel of the
LLE Network Extender. Versions of the LLE
Network Extender with the color-coded, 8-pin
screw connector will connect standard CAT-5
twisted-pair cable from the rear panel color coded
connector of the LLE Network Extender to the
supplied VM-186 RJ-45 connector (900 feet
maximum distance). Connect RJ-45 connector
of horn to VM-186 RJ-45 socket.