MUS0330202
03/10/2014
VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA
TEL: +34 948 321580 Fax: +34 948 326584 [email protected] www.valcomelton.com
71
5.2 TEMPERATURE
The tank temperature screen will show the actual tank temperature and
the tank temperature setpoint. For operator convenience, the right side
of the display screen alternately displays the Hose & Gun temperatures
(see the
Machine Adjustment
section for setting zone temperatures).
Press the Heater Key (or use the Navigation Buttons) to cycle through
the temperature screens until you reach the desired screen.
5.2.1 Setpoint and Actual Temperature
5.2.2 Temperature Status LEDs
The Control Panel contains LEDs that indicate the status of each
heated zone. When the zone is in warm-up mode, the zone LED will
illuminate green and stay on continuously. Once the zone reaches its
setpoint temperature, the LED will blink on and off indicating that the
heaters are switching on and off to maintain the setpoint temperature.
If the LED illuminates red, it indicates a fault for that zone. The status
bar will provide a more detailed explanation of the fault. Also, if the
fault triggers a temperature alarm, the Temperature Alarm LED will
illuminate red (see the
Machine Adjustment
section,
“Over
Temperature Alarm” and “Under Temperature Alarm,” for details).
Tank Heater LED
System Ready LED
Warning/Alarm LED
Hose Zone LEDs
Gun Zone LEDs
Tank Heater LED
System Ready LED
Warning/Alarm LED
Hose Zone LEDs
Gun Zone LEDs
Heater (temperature) Menu Key & LED
Actual Temperature
Setpoint Temperature