4.3. OTHER ADJUSTMENT
4.3.1 Ready Delay Time
When the Ready Delay Time is used, the System Ready LED will
illuminate a preset time after all of the zones reach their respective
temperature setpoints minus the System Ready Temperature Offset.
This feature allows the adhesive in the system to heat for an additional
period of time before the piston pump is enabled.
Once the zones have reached the System Ready Temperature, the
time remaining before the system is ready is displayed on the status
bar at the bottom of the screen.
The ready delay range is 1 minute to 120 minutes. The default factory
setting is ON at 15 minutes.
This parameter can be accessed in Password Level 2 or higher.