VAL VLC-12V10-1 Operation Manual Download Page 1

Operation Manual

                                                      Controller for LED Illumination 

VLC-12V10-1 

 

To use this LED controller with optimum performance and safety, please read this manual thoroughly before starting operation. 
Keep this manual for the whole product lifetime. 
The following warning symbols are used in this manual. Be sure to fully understand the contents. 

WARNING 

A warning denotes a hazard that can cause severe injury or death. 

   CAUTION 

A caution denotes a hazard that can cause injury or damage of equipment. 

 
1.Safety regulations 

WARNING

 

 

Do not open the chassis to avoid electric shock. 
High-voltage parts are inside. 

 

Use only VAL LED lighting unit. 
If you use with other lighting unit, over current may cause a fire or heat. 

 

 

CAUTION 

USE the extension or remote cables 3m maximum to prevent power drop by voltage reduction or malfunction by noise. 
Do not look at the LED directly. If you see the LED long time, your eyes may be damaged. 
Cleaning : Use wet cloth twisted well. 
Dispose the product conforming to the law in the region where the product is used. 

 
2.General Description 

VLC-12V10-1 is a controller for VAL LED lighting unit (10W max. 

*

). 

    It can be used with input voltage range with DC12V/1A. Remote control is also available. 

 
3.Confirming package contents 

Item 

Q’ty 

Main unit 

Output connector 

This instruction manual 

 
4.Operation 

 

(1) Connections  

Connect cable to terminal block by figure. 

CAUTION

 

Please be careful about polar character. 
Use output signal cable size AWG min.24 – max.20. 
Use flat head screwdriver. (Recommended width size 0.4x2.0mm) 
Do not use screwdriver with excessive force. 

(2) Manual control 

Light intensity is adjustable manually where the control volume on the front panel. 
Turn the volume anticlockwise, it becomes darker. Turn the volume clockwise, it becomes brighter.

 

 
5.External Signal Connector 

Caution 

Use output signal cable of 3m or shorter. 
Do not apply too high current and voltage. 
Do not use external connector except SELV circuit with reinforced insulation or a circuit with double insulation.

 

Pin assignment of Terminal block

 

No. 

Identification 

 

No.  Identification 

 

No. 

Identification 

DC 12V IN 

 

MANU/EXT.DC12-24V IN

 

 

LED+OUT 

DC 0V IN 

 

MANU/EXT.DC0V IN

 

 

10 

LED-OUT 

LED ON DC 0V IN / 

OFF DC12-24V IN

 

 

EXT.DC 0-5V IN 

 

 

 

LED ON/OFF DC0V IN

 

 

EXT.DC 0V IN 

 

 

 

 

 
 

 

 

 

 