4.9.4 RS-485 Cable 2 m and RS-485 Cable 10 m
RS-485 Cable 2 m and RS-485 Cable 10 m are designed for the standard connection:
operating power, heater power, and RS-485. The two-wire RS-485 loopback connections are
preconnected inside the cable.
Table 26 Connecting RS-485 Cable 2 m (228259SP) and RS-485 Cable 10 m (228260SP)
Power Supply
Wire Colors
Pin
Operating Power Supply
White
1
Operating Power Supply Ground
Gray-Pink
11
Heater Power Supply
Gray, Green, Pink
5, 6
Heater Power Supply Ground
Blue, Black, Red, Yellow
7, 8
Enclosure Ground
Shield
Shield
COM2
RS485 -
Brown
3,4
RS485 +
Red-Blue
14, 15
Communications Ground
Violet
10
4.9.5 Connector Signals
The following figure and table show the pin-out of the 17-pin M23 connector. The serial
output type of COM2 depends on the sensor configuration. Analog outputs are always
available from the connector.
Figure 31 Pins for 17-Pin M23 Connector
Chapter 4 – Installation
75
Summary of Contents for WINDCAP WMT700 Series
Page 1: ...M211095EN H User Guide Vaisala WINDCAP Ultrasonic Wind Sensor Series WMT700 ...
Page 32: ...WMT700 User Guide M211095EN H 30 ...
Page 100: ...WMT700 User Guide M211095EN H 98 ...
Page 168: ...4 Remove the verifier WMT700 User Guide M211095EN H 166 ...
Page 174: ...WMT700 User Guide M211095EN H 172 ...
Page 182: ...WMT700 User Guide M211095EN H 180 ...
Page 194: ...WMT700 User Guide M211095EN H 192 ...
Page 198: ...WMT700 User Guide M211095EN H 196 ...
Page 201: ...Appendix G Certificate Appendix G Certificate 199 ...
Page 202: ...WMT700 User Guide M211095EN H 200 ...
Page 208: ...WMT700 User Guide M211095EN H 206 ...
Page 209: ......
Page 210: ...www vaisala com ...