MWV
Fixed text
<dir>
Wind angle: 0 to 359 degrees
<ref>
Reference: R = relative
<spd>
Wind speed
<uni>
Wind speed unit:
K = Kilometers per hour
M = Meters per second
N = Knots
<sta>
Status:
A = Valid data
V = Invalid data
*
Fixed text
<chk>
Checksum (8-bit XOR, excluding $ and *)
<CR>
Carriage return code, ASCII 0DH
<LF>
Line feed code, ASCII 0AH
Missing Readings
If data is missing due to a measurement problem, the NMEA messages show "V" in the
status field. Wind speed and wind direction fields are left empty.
5.24 WS425 A/B ASCII Profile
In Vaisala WINDCAP Ultrasonic Wind Sensor WS425 User's Guide, this profile was called
the Handar mode.
The following table lists the configurable parameters and their allowed and default values
for the WS425 A/B ASCII Profile.
Parameter
Default
Value
Profile-Specific Allowed Values
Description
autoInt
1
0.25 ... 1000
Resolution: 0.25
Automatic message interval in
seconds.
Do not select a message interval
that is shorter than the time it
takes to send a data message.
autoPort
1
• 1= COM1 port
• 2= COM2 port
Serial port to which WMT700
sends automatic data messages.
Chapter 5 – Operation
147
Summary of Contents for WINDCAP WMT700 Series
Page 1: ...M211095EN H User Guide Vaisala WINDCAP Ultrasonic Wind Sensor Series WMT700 ...
Page 32: ...WMT700 User Guide M211095EN H 30 ...
Page 100: ...WMT700 User Guide M211095EN H 98 ...
Page 168: ...4 Remove the verifier WMT700 User Guide M211095EN H 166 ...
Page 174: ...WMT700 User Guide M211095EN H 172 ...
Page 182: ...WMT700 User Guide M211095EN H 180 ...
Page 194: ...WMT700 User Guide M211095EN H 192 ...
Page 198: ...WMT700 User Guide M211095EN H 196 ...
Page 201: ...Appendix G Certificate Appendix G Certificate 199 ...
Page 202: ...WMT700 User Guide M211095EN H 200 ...
Page 208: ...WMT700 User Guide M211095EN H 206 ...
Page 209: ......
Page 210: ...www vaisala com ...