ID Character <id>
Checksum <CS>
Polling String
I
7A
$WIPIQ,*7A<cr><lf>
J
79
$WIPJQ,*79<cr><lf>
K
78
$WIPKQ,*78<cr><lf>
L
7F
$WIPLQ,*7F<cr><lf>
M
7E
$WIPMQ,*7E<cr><lf>
N
7D
$WIPNQ,*7D<cr><lf>
O
7C
$WIPOQ,*7C<cr><lf>
4.2.3 Service Connection
You can configure the device and view the status information through the service connection.
The same interface is used for both the data transmission and the connection. When you open
the connection with the
OPEN
command, the data transmission and query are disabled as long
as the service connection remains open.
When you change parameter values, you must reset with the
RESET
command or
by powering up to get the new parameters into use.
The parameter setting commands are not case-sensitive. The device ID is case-
sensitive.
Enter commands on a single line and terminate with a line feed <lf> or a carriage return <cr>
character. Separate parameters and values by a space. You can set only one parameter with a
single command.
More information
‣
Configuring WAC155 for WA25 (page 26)
4.3 Configuration Commands
The following table lists the commands available in the service connection.
Table 8 Configuration Commands
Command
Description
OPEN
Opens the service connection.
Chapter 4 – Operation