USER'S GUIDE____________________________________________________________________
2 ___________________________________________________________________ M211024EN-B
Terminal Application Settings..............................................28
List of Serial Commands .......................................................30
Device Information and Status..............................................31
Show Device Information ....................................................31
Show Quantities ..................................................................32
Show Calibration Info ..........................................................32
Show Analog Output Status ................................................32
Show Firmware Version ......................................................33
Serial Line Output Commands ..............................................33
Start Measurement Output ..................................................33
Stop Measurement Output ..................................................33
Set Output Interval...............................................................34
Output a Reading Once.......................................................34
Calibration Commands ..........................................................35
Calibrate Humidity Measurement ........................................35
Calibrate Temperature Measurement .................................36
Calibrate Capacitance Measurement ..................................37
View User Adjustment Parameters .....................................38
Set User Adjustment Parameters........................................38
Zero the Trimmers ...............................................................39
Calibrate Analog Output ......................................................39
Configuring Serial Line Operation ........................................40
Set Serial Line Settings .......................................................40
Set Terminal Echo ...............................................................40
Set Module Address ............................................................41
Set Serial Interface Mode....................................................41
Configuring Measurement Parameters ................................42
Set Environmental Compensation Values...........................42
Set Temporary Pressure Compensation Value...................43
Configuring Analog Output ...................................................44
Set Analog Output Mode .....................................................44
Select Analog Output Quantity and Scaling ........................44
Test the Analog Output .......................................................45
Other Commands ...................................................................46
Display Command List ........................................................46
Enable Advanced Commands.............................................46
Display the Currently Active Errors .....................................46
Connecting to the Module in POLL Mode ...........................47
Closing the Connection in POLL Mode ...............................47
Save Changed Settings.......................................................47
Restore Saved Settings.......................................................48
Reset the Module ................................................................48
Restore Factory Settings .....................................................48
CHAPTER 5
MAINTENANCE............................................................................................49
Changing the Filter .................................................................49
Changing the Sensor .............................................................49
Calibration ...............................................................................51
Calibration and Adjustment Using Trimmers ......................52
Calibration and Adjustment Using Serial Line ....................53
Humidity Calibration (RHCAL).............................................54
Temperature Calibration (CT) .............................................56
Capacitance Calibration (CRH) ...........................................58