![Vaisala AWS310-SITE Integration Manual Download Page 61](http://html2.mh-extra.com/html/vaisala/aws310-site/aws310-site_integration-manual_3200537061.webp)
5. In the
COM 5
window, set the following:
Serial link type
Type of serial link:
RS
‑
485/2
‑
wire
.
Baud rate
Connection speed:
9600
.
Data bits
Number of data bits used in characters:
8
.
Parity bits
Number of parity bits used:
None
.
Stop bits
Number of stop bits used:
1
.
6. To save the changes, select
OK > OK
.
5.7 Exporting current station
configuration
Administrators can export the current station settings to:
• Use the same station configuration on another station.
• Take a backup copy of the current settings.
The backup copy is the only way to restore any manual changes made through the Web UI
after the last system settings import. You can take a backup copy anytime.
When the station is operational, Vaisala recommends that you always export the current
settings as a backup before making any changes to the configuration.
Chapter 5 – Configuration
59