Implementing the setting if the heat pump
fails

If the fault message

Restricted operation/ comfort pro-

tection Inactive

appears on the display, the heat pump has

failed and the system control enters limp home mode. The
back-up boiler now supplies the heating installation with
heating energy. During installation, the competent person
has restricted the temperature for limp home mode. You can
feel that the domestic hot water and heating are not becom-
ing very hot.

While you wait for the competent person to come, you can
use the rotary knob to implement the following settings:

Inactive

: The system control works in limp home mode;

heating and domestic hot water become moderately hot.

Heating

: The back-up boiler takes over the heating mode;

the heating becomes hot, the domestic hot water is cold.

DHW

: The back-up boiler takes over the domestic hot water

mode; the domestic hot water becomes hot, the heating is
cold.

DHW+heat.

: The back-up boiler takes over the heating and

domestic hot water mode; the heating and the domestic hot
water become hot.

The back-up boiler is not as efficient as the heat pump,
meaning that using only the back-up boiler to generate heat
is expensive.

If you want to implement settings on the system control, click

Back

and the basic display appears in the display. After five

minutes of no operation, the fault message appears again in
the display.

7

Care

7.1

Caring for the product

Clean the casing with a damp cloth and a little solvent-
free soap.

Do not use sprays, scouring agents, detergents, solvents
or cleaning agents that contain chlorine.

8

Decommissioning

8.1

Decommissioning the product

If you want to replace or remove the product, you must de-
commission the heating installation.

This work should be carried out by a competent person.

8.2

Recycling and disposal

Observe the recycling and disposal information in the
installation instructions.

9

Guarantee and customer service

9.1

Guarantee

We only grant a Vaillant manufacturers warranty if a suitably
qualified engineer has installed the system in accordance
with Vaillant instructions. The system owner will be granted
a warranty in accordance with the Vaillant terms and condi-
tions. All requests for work during the guarantee period must
be made to Vaillant Service Solutions.

9.2

Customer service

For contact details for our customer service department, you
can write to the address that is provided on the back page,
or you can visit www.vaillant.co.uk.

10 Technical data

10.1

Product data in accordance with EU
Ordinance no. 811/2013, 812/2013

On units with integrated weather-compensated controls, in-
cluding a room thermostat function that can be activated, the
seasonal room-heating efficiency always includes the cor-
rection factor for control technology class VI. The seasonal
room-heating efficiency may deviate if this function is deac-
tivated.

Temperature control class

VI

Contribution to the seasonal room-heat-
ing energy efficiency ɳs

4.0 %

Summary of Contents for VRC 700/6

Page 1: ...en Operating instructions Weather compensated system control VRC 700 6 0020262548_01 28 11 2022...

Page 2: ...4 Operation 5 4 1 Operating structure 5 4 2 Basic display 6 4 3 Operating concept 6 5 Operating and display functions 8 5 1 Information 8 5 2 Settings 10 5 3 Operating modes 14 5 4 Advanced functions...

Page 3: ...physical sensory or mental capabil ities or lack of experience and knowledge if they have been given supervision or instruc tion concerning use of the product in a safe way and understand the hazards...

Page 4: ...flow temperature of the heating installation If the outdoor temperature increases the system control reduces the flow temperature The system control responds to the fluctuations in the outdoor temper...

Page 5: ...ine 3 9 CE marking The CE marking shows that the products comply with the basic requirements of the applicable directives as stated on the declaration of conformity The declaration of conformity can b...

Page 6: ...energy Off Day Set back off Empty line 4 2 3 2 Basic display for the Cooling operating mode Mode Time periods Symbol Information field Auto On Desired cooling temp Off Empty line Day Desired cooling...

Page 7: ...nge to the Max vent stage Day Set back Direct permanent change to the Max vent stge Night 4 3 1 4 Desired temperature in the Manual cooling advanced function Mode Time periods Effect Activated On Dire...

Page 8: ...inform ation that provides an overview of the current system status and current settings that you can change there 5 1 1 1 System Menu Information System status Fault status If no maintenance is requ...

Page 9: ...set the desired set back temperature for the zone Set back temp heat is the temperature that you want to have in the rooms during the night or when you are away from home night mode Menu Information S...

Page 10: ...e total yield is displayed on the bottom right The highest value achieved in one month for the last two years is dis played in the top right 5 1 2 4 Diagram Reading the electrical consumption Menu Inf...

Page 11: ...ge 12 You can create up to three time periods for each individual day and for predefined blocks Monday Friday Saturday Sunday Monday Sunday When entering time periods for individual days or blocks the...

Page 12: ...n Within the time period the circulation is switched on Outside the time period the circulation is switched off 5 2 3 8 Setting the Ventilation time programme Menu Time programmes Ventilation The time...

Page 13: ...g Button lock Menu Basic settings Display Button lock You can use this function to activate the button lock After one minute of not pressing any button or operating the rotary knob the button lock is...

Page 14: ...ogrammes or for Everything to the default setting Menu Basic settings Default setting Time pro grammes With Time programmes you reset all the settings you have made in the Time programmes function to...

Page 15: ...of air using the value that you set in the Max vent stage Day ventilation level Set back The operating mode constantly controls the ex change of air using the value that you set in the Max vent stge N...

Page 16: ...st The Cylinder boost advanced function heats the water in the domestic hot water cylinder until it reaches the set desired temperature Domestic hot water The advanced function is active for one hour...

Page 17: ...ears again in the display 7 Care 7 1 Caring for the product Clean the casing with a damp cloth and a little solvent free soap Do not use sprays scouring agents detergents solvents or cleaning agents t...

Page 18: ...ription of the functions for ZONE1 also applies for all available zones Setting level Values Unit Increment select Default setting Min Max Information System status System Fault status Current value N...

Page 19: ...ast month kWh Hot water Electricity Total value since start up kWh Fuel Total value since start up kWh Information Consumption History Heating Electricity Total value since start up kWh Fuel Total val...

Page 20: ...NE1 Cooling Time programmes Circulation Time programmes Ventilation Individual days and blocks Monday Tuesday Wednes day Thursday Friday Sat urday Sunday and Monday Friday Saturday Sunday Monday Sunda...

Page 21: ...Button lock off On off Preferred display Heating Cooling Vent Heating Basic settings Costs Tariff for aux heater 1 999 1 12 Low tariff elec rate 1 999 1 16 High tariff elec rate 1 999 1 20 Basic setti...

Page 22: ...Fault Heat generator 1 the specific fault code e g F 33 and the specific heat generator appear behind F in the display Heat generator faults 1 Carry out a Reset fault message Page 16 2 If the fault p...

Page 23: ...basic display 6 Outdoor temperature setting the offset 14 P Party 16 Preventing a malfunction 5 R Reading the article number 5 10 Reading the electrical consumption 10 Reading the environment yield 1...

Page 24: ...24 Operating instructions 0020262548_01 Time programme 11 quick setting 11 Setting 11 V Ventilation 4 Ventilation boost 16 Ventilation level 11 Z Zone 4 10 Zone in the basic display 6...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...isher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 2191 18 0 Fax 49 2191 18 2810 info vaillant de www vaillant de These instructions or parts thereof are protected by copyrigh...

Reviews: