background image

12

Operating instructions 0020262548_01

Individual dates vary from 

the selected time programme

Mo-Su.

OK

Back

If you press the right-hand selection button

Select

, a mes-

sage appears on the display which informs you about differ-
ent time periods. You do not need to adjust the times.

You can use the right-hand selection button

OK

to display

and change the set times for the block marked with !!.

5.2.3.4 Setting the Heating time programme

Menu

Time programmes

ZONE1

The time programmes are only effective for the

Heat-

ing

operating mode in automatic mode. Within the time

periods, the system control brings the temperature of
the connected rooms to the set desired temperature

Day

temp. heating

. Outside of these time periods, the sys-

tem control switches to the operating mode that the com-
petent person has set:

Eco

or

Set-back temp. heat.

. If

the competent person has left the factory setting

Eco

, the

system control switches off the heating function.

Setting the

Heating

operating mode. (

Page 14)

5.2.3.5 Setting the Cooling time programme

Menu

Time programmes

ZONE1

:

Cooling

The time programmes are only effective in the

Cooling

mode and the

Manual cooling

advanced function. In

each set time period, the desired temperature that you
set in the

Desired temperatures

function applies. Within

the time periods, the zone cools the living areas to the
desired

Day temp. cooling

temperature. Outside this

time period, there is no cooling.

5.2.3.6 Setting the domestic hot water generation

time programme

Menu

Time programmes

DHW circuit

The time programmes are only effective for domestic hot
water generation in automatic mode. In each set time
period, the desired

Domestic hot water

temperature

applies. At the end of a time period, the system control
switches the domestic hot water generation off until the
start of the next time period.

5.2.3.7 Setting the time programme Circulation

Menu

Time programmes

Circulation

The time programmes are only effective for circulation
in Automatic mode. The set time periods determine the
operating times for circulation. Within the time period, the
circulation is switched on. Outside the time period, the
circulation is switched off.

5.2.3.8 Setting the Ventilation time programme

Menu

Time programmes

Ventilation

The time programmes are only effective for ventilation
in automatic mode. In each set time period, the ventila-
tion level that you set in the

Ventilation

function applies.

Within the time period, the system control regulates the
ventilation unit to

Max. vent. stage: Day

as a maximum.

Outside the time period, the system control regulates the
ventilation unit to

Max. vent. stge: Night

as a maximum.

5.2.3.9 Setting the High tariff time programme

Menu

Time programmes

High tariff

You can use this function to set when the high tariff or the
low tariff should be used to calculate the costs.

Within the time period: For the high tariff

Outside of the time period: For the low tariff

The times of high tariff depend on your energy supply com-
pany.

If the energy supply company only offers one tariff, you do
not need to set any time periods. The cost for the electricity
is calculated using one tariff.

Setting costs (

Page 13)

5.2.4

Days away from home scheduling

Menu

Days away from home scheduling

You can use this function to set a period of time and a
temperature for the days that you are away from home.

Heating installation operation during the set time
period

The domestic hot water is not being heated.

The previously set temperature applies for all zones.

The ventilation runs at the lowest ventilation level.

The cooling is switched off.

While the

Days away from home scheduling

function is

activated, it has priority over the set operating mode. At the
end of the specified period, or if you cancel the function, the
heating installation returns to the pre-set mode.

5.2.5

Day at home scheduling

Menu

Days at home scheduling

In the specified period, the heating installation works in
the

Automatic mode

mode and uses the day settings for

Sunday

, which were set using the

Time programmes

function. At the end of the specified period, or if you can-
cel the function, the heating installation returns to the pre-
set mode.

5.2.6

Select language

Menu

Basic settings

Language

You can use this function to change to the language that
you want to appear in the display.

Summary of Contents for VRC 700/6

Page 1: ...en Operating instructions Weather compensated system control VRC 700 6 0020262548_01 28 11 2022...

Page 2: ...4 Operation 5 4 1 Operating structure 5 4 2 Basic display 6 4 3 Operating concept 6 5 Operating and display functions 8 5 1 Information 8 5 2 Settings 10 5 3 Operating modes 14 5 4 Advanced functions...

Page 3: ...physical sensory or mental capabil ities or lack of experience and knowledge if they have been given supervision or instruc tion concerning use of the product in a safe way and understand the hazards...

Page 4: ...flow temperature of the heating installation If the outdoor temperature increases the system control reduces the flow temperature The system control responds to the fluctuations in the outdoor temper...

Page 5: ...ine 3 9 CE marking The CE marking shows that the products comply with the basic requirements of the applicable directives as stated on the declaration of conformity The declaration of conformity can b...

Page 6: ...energy Off Day Set back off Empty line 4 2 3 2 Basic display for the Cooling operating mode Mode Time periods Symbol Information field Auto On Desired cooling temp Off Empty line Day Desired cooling...

Page 7: ...nge to the Max vent stage Day Set back Direct permanent change to the Max vent stge Night 4 3 1 4 Desired temperature in the Manual cooling advanced function Mode Time periods Effect Activated On Dire...

Page 8: ...inform ation that provides an overview of the current system status and current settings that you can change there 5 1 1 1 System Menu Information System status Fault status If no maintenance is requ...

Page 9: ...set the desired set back temperature for the zone Set back temp heat is the temperature that you want to have in the rooms during the night or when you are away from home night mode Menu Information S...

Page 10: ...e total yield is displayed on the bottom right The highest value achieved in one month for the last two years is dis played in the top right 5 1 2 4 Diagram Reading the electrical consumption Menu Inf...

Page 11: ...ge 12 You can create up to three time periods for each individual day and for predefined blocks Monday Friday Saturday Sunday Monday Sunday When entering time periods for individual days or blocks the...

Page 12: ...n Within the time period the circulation is switched on Outside the time period the circulation is switched off 5 2 3 8 Setting the Ventilation time programme Menu Time programmes Ventilation The time...

Page 13: ...g Button lock Menu Basic settings Display Button lock You can use this function to activate the button lock After one minute of not pressing any button or operating the rotary knob the button lock is...

Page 14: ...ogrammes or for Everything to the default setting Menu Basic settings Default setting Time pro grammes With Time programmes you reset all the settings you have made in the Time programmes function to...

Page 15: ...of air using the value that you set in the Max vent stage Day ventilation level Set back The operating mode constantly controls the ex change of air using the value that you set in the Max vent stge N...

Page 16: ...st The Cylinder boost advanced function heats the water in the domestic hot water cylinder until it reaches the set desired temperature Domestic hot water The advanced function is active for one hour...

Page 17: ...ears again in the display 7 Care 7 1 Caring for the product Clean the casing with a damp cloth and a little solvent free soap Do not use sprays scouring agents detergents solvents or cleaning agents t...

Page 18: ...ription of the functions for ZONE1 also applies for all available zones Setting level Values Unit Increment select Default setting Min Max Information System status System Fault status Current value N...

Page 19: ...ast month kWh Hot water Electricity Total value since start up kWh Fuel Total value since start up kWh Information Consumption History Heating Electricity Total value since start up kWh Fuel Total val...

Page 20: ...NE1 Cooling Time programmes Circulation Time programmes Ventilation Individual days and blocks Monday Tuesday Wednes day Thursday Friday Sat urday Sunday and Monday Friday Saturday Sunday Monday Sunda...

Page 21: ...Button lock off On off Preferred display Heating Cooling Vent Heating Basic settings Costs Tariff for aux heater 1 999 1 12 Low tariff elec rate 1 999 1 16 High tariff elec rate 1 999 1 20 Basic setti...

Page 22: ...Fault Heat generator 1 the specific fault code e g F 33 and the specific heat generator appear behind F in the display Heat generator faults 1 Carry out a Reset fault message Page 16 2 If the fault p...

Page 23: ...basic display 6 Outdoor temperature setting the offset 14 P Party 16 Preventing a malfunction 5 R Reading the article number 5 10 Reading the electrical consumption 10 Reading the environment yield 1...

Page 24: ...24 Operating instructions 0020262548_01 Time programme 11 quick setting 11 Setting 11 V Ventilation 4 Ventilation boost 16 Ventilation level 11 Z Zone 4 10 Zone in the basic display 6...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...isher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 2191 18 0 Fax 49 2191 18 2810 info vaillant de www vaillant de These instructions or parts thereof are protected by copyrigh...

Reviews: